You need JavaScript to view this

Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension

Abstract

Four artificial intelligence tools developed at the Instituto de Investigaciones Electricas (IIE) to support the analysis of high tension insulator flaming are described. The first tool builds up a decision tree departing from historical data, the other 3 tools operate departing from the decision tree previously created to generate production rules, function as an expert system and make tests with many already known cases. These tools could predict the impending occurrence of flaming with enough time allowance for the insulators to be cleaned, since the traditional practice is the periodical cleaning of the insulators and this is not always adequate since the cleaning teams are limited, and the action of the environment is not always constant and for that reason insulators that do not need it are cleaned and vice-versa [Espanol] Se describen 4 herramientas de inteligencia artificial desarrolladas en el Instituto de Investigaciones Electricas (IIE) para apoyar al analisis de flameos en aisladores de alta tension. La primera herramienta construye el arbol de decision a partir de datos historicos; las otras 3 herramientas operan a partir del arbol de decision previamente creado para generar reglas de produccion, funcionar a la manera de un sistema experto y hacer pruebas con  More>>
Authors:
Rodriguez Ortiz, Guillermo; Mejia Lavalle, Manuel; Montoya Tena, Gerardo [1] 
  1. Instituto de Investigaciones Electricas, Cuernavaca (Mexico)
Publication Date:
Dec 31, 1996
Product Type:
Miscellaneous
Report Number:
ETDE-MX-98006435
Reference Number:
SCA: 240300; PA: MX-98:000200; EDB-98:093254; SN: 98001998871
Resource Relation:
Other Information: DN: Nov-Dec 1996 issue; PBD: 1996; Related Information: Is Part Of IIE Bulletin: selected articles from 1996 issues of `boletin iie`; PB: [275] p.; Boletin IIE, v. 20/6
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; ARTIFICIAL INTELLIGENCE; EXPERT SYSTEMS; ELECTRICAL INSULATORS; COMPUTER CODES; POWER TRANSMISSION LINES; ELECTRICAL EQUIPMENT; NUMERICAL DATA; FAILURES; FIRES
OSTI ID:
639016
Research Organizations:
Instituto de Investigaciones Electricas, Cuernavaca (Mexico)
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Journal ID: ISSN 0185-0059; Other: ON: DE98006435; TRN: MX9800200
Availability:
Available from Unidad de Informacion Tecnologica, Instituto de Investigaciones Electricas, Av. Reforma 113, col. Palmira, 62490 Temixco, Mor., Mexico, Tel: (73) 18 38 11 ext. 7138, Fax: (73) 18 24 61; OSTI as DE98006435
Submitting Site:
MX
Size:
pp. 240-244
Announcement Date:
Sep 16, 1998

Citation Formats

Rodriguez Ortiz, Guillermo, Mejia Lavalle, Manuel, and Montoya Tena, Gerardo. Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension. Mexico: N. p., 1996. Web.
Rodriguez Ortiz, Guillermo, Mejia Lavalle, Manuel, & Montoya Tena, Gerardo. Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension. Mexico.
Rodriguez Ortiz, Guillermo, Mejia Lavalle, Manuel, and Montoya Tena, Gerardo. 1996. "Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension." Mexico.
@misc{etde_639016,
title = {Artificial intelligence tools to support the analysis of the high tension insulator flaming; Herramientas de inteligencia artificial de apoyo al analisis de flameos en aisladores de alta tension}
author = {Rodriguez Ortiz, Guillermo, Mejia Lavalle, Manuel, and Montoya Tena, Gerardo}
abstractNote = {Four artificial intelligence tools developed at the Instituto de Investigaciones Electricas (IIE) to support the analysis of high tension insulator flaming are described. The first tool builds up a decision tree departing from historical data, the other 3 tools operate departing from the decision tree previously created to generate production rules, function as an expert system and make tests with many already known cases. These tools could predict the impending occurrence of flaming with enough time allowance for the insulators to be cleaned, since the traditional practice is the periodical cleaning of the insulators and this is not always adequate since the cleaning teams are limited, and the action of the environment is not always constant and for that reason insulators that do not need it are cleaned and vice-versa [Espanol] Se describen 4 herramientas de inteligencia artificial desarrolladas en el Instituto de Investigaciones Electricas (IIE) para apoyar al analisis de flameos en aisladores de alta tension. La primera herramienta construye el arbol de decision a partir de datos historicos; las otras 3 herramientas operan a partir del arbol de decision previamente creado para generar reglas de produccion, funcionar a la manera de un sistema experto y hacer pruebas con muchos casos conocidos. Estas herramientas podrian predecir la ocurrencia inminente del flameo con tiempo suficiente para que los aisladores se limpien, ya que la forma tradicional es limpiar periodicamente los aisladores y esto a veces no es adecuado debido a que las cuadrillas de limpieza son limitadas, ademas de que la accion del medio ambiente no es constante y es por eso que a veces se limpian aisladores que no lo necesitan o viceversa}
place = {Mexico}
year = {1996}
month = {Dec}
}