Effect of the blades and seals system wear on steam turbine efficiency and power; Efecto del desgaste del sistema de alabes y sellos sobre la eficiencia y potencia de las turbinas de vapor

Abstract

The implementation of a method for steam turbine evaluation through the measured geometry in the flow channel and its operating conditions, is presented. This method, previously developed, allows the identification and quantification of the power and efficiency loss due to the wear of its elements (worn or bent blades, worn seals, deposits, etc.); the benefit that is obtained is a more precise knowledge on the turbine behavior and a basis is acquired to give priority to the maintenance work, from the stand point of energy utilization. In this paper, the power and efficiency loss of a 300 MW steam turbine is located and evaluated, a sensibility analysis is presented for the typical elements that cause the deterioration of the efficiency in this type of turbines. [Espanol] Se presenta la implementacion de un metodo de evaluacion de turbinas de vapor a partir de la geometria medida del canal de flujo y sus condiciones de operacion. Este metodo, previamente desarrollado, permite identificar y cuantificar las perdidas de potencia y eficiencia debido al desgaste de sus elementos (alabes desgastados o doblados, sellos desgastados, depositos, etcetera); el beneficio que se obtiene es un conocimiento mas preciso del comportamiento de la turbina y que se  More>>
Authors:
Campos Amezcua, Alfonso; Kubiak Szyszka, Janusz [1] 
  1. Instituto de Investigaciones Electricas, Cuernavaca (Mexico)
Publication Date:
Dec 31, 1997
Product Type:
Miscellaneous
Report Number:
ETDE-MX-98775140
Reference Number:
SCA: 200104; PA: MX-98:000124; EDB-98:086432; SN: 98001995062
Resource Relation:
Journal Name: Boletin IIE; Journal Volume: 21; Journal Issue: 1; Other Information: DN: Jan-Feb 1997 issue; PBD: 1997; Related Information: Is Part Of IIE Bulletin: selected articles from 1997 issues of `boletin iie`; PB: [300] p.; Boletin IIE, v. 21
Subject:
20 FOSSIL-FUELED POWER PLANTS; TURBINE BLADES; STEAM TURBINES; EVALUATION; POWER LOSSES; MECHANICAL TESTS; NUMERICAL DATA; WEAR; EFFICIENCY
OSTI ID:
638668
Research Organizations:
Instituto de Investigaciones Electricas, Cuernavaca (Mexico)
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Journal ID: BOIID8; ISSN 0185-0059; Other: ON: TI98775140; TRN: MX9800124
Availability:
Available from Unidad de Informacion Tecnologica, Instituto de Investigaciones Electricas, Av. Reforma 113, col. Palmira, 62490 Temixco, Mor., Mexico, Tel: (73) 18 38 11 ext. 7138, Fax: (73) 18 24 61; OSTI as TI98775140
Submitting Site:
MX
Size:
pp. 34-39
Announcement Date:
Sep 15, 1998

Citation Formats

Campos Amezcua, Alfonso, and Kubiak Szyszka, Janusz. Effect of the blades and seals system wear on steam turbine efficiency and power; Efecto del desgaste del sistema de alabes y sellos sobre la eficiencia y potencia de las turbinas de vapor. Mexico: N. p., 1997. Web.
Campos Amezcua, Alfonso, & Kubiak Szyszka, Janusz. Effect of the blades and seals system wear on steam turbine efficiency and power; Efecto del desgaste del sistema de alabes y sellos sobre la eficiencia y potencia de las turbinas de vapor. Mexico.
Campos Amezcua, Alfonso, and Kubiak Szyszka, Janusz. 1997. "Effect of the blades and seals system wear on steam turbine efficiency and power; Efecto del desgaste del sistema de alabes y sellos sobre la eficiencia y potencia de las turbinas de vapor." Mexico.
@misc{etde_638668,
title = {Effect of the blades and seals system wear on steam turbine efficiency and power; Efecto del desgaste del sistema de alabes y sellos sobre la eficiencia y potencia de las turbinas de vapor}
author = {Campos Amezcua, Alfonso, and Kubiak Szyszka, Janusz}
abstractNote = {The implementation of a method for steam turbine evaluation through the measured geometry in the flow channel and its operating conditions, is presented. This method, previously developed, allows the identification and quantification of the power and efficiency loss due to the wear of its elements (worn or bent blades, worn seals, deposits, etc.); the benefit that is obtained is a more precise knowledge on the turbine behavior and a basis is acquired to give priority to the maintenance work, from the stand point of energy utilization. In this paper, the power and efficiency loss of a 300 MW steam turbine is located and evaluated, a sensibility analysis is presented for the typical elements that cause the deterioration of the efficiency in this type of turbines. [Espanol] Se presenta la implementacion de un metodo de evaluacion de turbinas de vapor a partir de la geometria medida del canal de flujo y sus condiciones de operacion. Este metodo, previamente desarrollado, permite identificar y cuantificar las perdidas de potencia y eficiencia debido al desgaste de sus elementos (alabes desgastados o doblados, sellos desgastados, depositos, etcetera); el beneficio que se obtiene es un conocimiento mas preciso del comportamiento de la turbina y que se tiene una base para dar prioridad a los trabajos de mantenimiento desde el punto de vista de aprovechamiento de la energia. En este articulo se localizan y evaluan las perdidas de potencia y eficiencia de una turbina de vapor de 300 MW, ademas, se presenta un analisis de sensibilidad para los elementos tipicos que originan el deterioro de la eficiencia en este tipo de turbinas.}
journal = []
issue = {1}
volume = {21}
place = {Mexico}
year = {1997}
month = {Dec}
}