Abstract
Viewing the development of the pulsed, low resolution NMR spectrometers for quantitative analysis, the electronic part of a NMR spectrometer has first been constructed, based on a 1.4 Tesla magnet of a 60 MHz Varian device, with a gap increased to 23 mm, therefore reducing the field to .66 Tesla (28 MHz for the hydrogen). For the complete construction of the spectrometer in Brazil, a permanent magnet for NMR has also been constructed 9 refs., 3 figs.
Colnago, Luiz Alberto;
Martins Neto, Ladislau;
Oste, Rene de
[1]
- Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA), Sao Carlos, SP (Brazil). Nucleo de Pesquisa e Desenvolvimento de Instrumentacao Agropecuaria
Citation Formats
Colnago, Luiz Alberto, Martins Neto, Ladislau, and Oste, Rene de.
Construction of a NMR permanent magnet; Construcao de um ima permanente para RMN.
Brazil: N. p.,
1991.
Web.
Colnago, Luiz Alberto, Martins Neto, Ladislau, & Oste, Rene de.
Construction of a NMR permanent magnet; Construcao de um ima permanente para RMN.
Brazil.
Colnago, Luiz Alberto, Martins Neto, Ladislau, and Oste, Rene de.
1991.
"Construction of a NMR permanent magnet; Construcao de um ima permanente para RMN."
Brazil.
@misc{etde_636793,
title = {Construction of a NMR permanent magnet; Construcao de um ima permanente para RMN}
author = {Colnago, Luiz Alberto, Martins Neto, Ladislau, and Oste, Rene de}
abstractNote = {Viewing the development of the pulsed, low resolution NMR spectrometers for quantitative analysis, the electronic part of a NMR spectrometer has first been constructed, based on a 1.4 Tesla magnet of a 60 MHz Varian device, with a gap increased to 23 mm, therefore reducing the field to .66 Tesla (28 MHz for the hydrogen). For the complete construction of the spectrometer in Brazil, a permanent magnet for NMR has also been constructed 9 refs., 3 figs.}
place = {Brazil}
year = {1991}
month = {Dec}
}
title = {Construction of a NMR permanent magnet; Construcao de um ima permanente para RMN}
author = {Colnago, Luiz Alberto, Martins Neto, Ladislau, and Oste, Rene de}
abstractNote = {Viewing the development of the pulsed, low resolution NMR spectrometers for quantitative analysis, the electronic part of a NMR spectrometer has first been constructed, based on a 1.4 Tesla magnet of a 60 MHz Varian device, with a gap increased to 23 mm, therefore reducing the field to .66 Tesla (28 MHz for the hydrogen). For the complete construction of the spectrometer in Brazil, a permanent magnet for NMR has also been constructed 9 refs., 3 figs.}
place = {Brazil}
year = {1991}
month = {Dec}
}