Abstract
Indoor thermal environment of a vehicle was evaluated by a numerical simulation. A numerical simulation using the equivalent temperature measured with the thermal manikin was conducted. Numerical manikin was improved and convective and radiative heat transfer at each body surface was described in detail. Comparative examination using the calculation results by the numerical simulation was also conducted. 3 refs., 8 figs., 2 tabs.
Matsunaga, K;
Sudo, F;
[1]
Tanabe, S
[2]
- Isuzu Motors Ltd., Tokyo (Japan)
- Ochanomizu Univ., Tokyo (Japan)
Citation Formats
Matsunaga, K, Sudo, F, and Tanabe, S.
Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka.
Japan: N. p.,
1997.
Web.
Matsunaga, K, Sudo, F, & Tanabe, S.
Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka.
Japan.
Matsunaga, K, Sudo, F, and Tanabe, S.
1997.
"Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka."
Japan.
@misc{etde_625105,
title = {Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka}
author = {Matsunaga, K, Sudo, F, and Tanabe, S}
abstractNote = {Indoor thermal environment of a vehicle was evaluated by a numerical simulation. A numerical simulation using the equivalent temperature measured with the thermal manikin was conducted. Numerical manikin was improved and convective and radiative heat transfer at each body surface was described in detail. Comparative examination using the calculation results by the numerical simulation was also conducted. 3 refs., 8 figs., 2 tabs.}
place = {Japan}
year = {1997}
month = {Oct}
}
title = {Evaluation of indoor thermal environment with improved 65 nodes thermoreguration model; Kairyogata 65 bunkatsu taion chosetsu model wo mochiita shashitsunai onnetsu kankyo hyoka}
author = {Matsunaga, K, Sudo, F, and Tanabe, S}
abstractNote = {Indoor thermal environment of a vehicle was evaluated by a numerical simulation. A numerical simulation using the equivalent temperature measured with the thermal manikin was conducted. Numerical manikin was improved and convective and radiative heat transfer at each body surface was described in detail. Comparative examination using the calculation results by the numerical simulation was also conducted. 3 refs., 8 figs., 2 tabs.}
place = {Japan}
year = {1997}
month = {Oct}
}