Abstract
The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.
Feher, I;
Andrasi, A;
Koblinger, L;
Zombori, P;
Szabo, P P
[1]
- Hungarian Academy of Sciences, Budapest. Central Research Inst. for Physics
Citation Formats
Feher, I, Andrasi, A, Koblinger, L, Zombori, P, and Szabo, P P.
Effects of activity inhomogeneities in walls on the external gamma doses in rooms.
United Kingdom: N. p.,
1984.
Web.
Feher, I, Andrasi, A, Koblinger, L, Zombori, P, & Szabo, P P.
Effects of activity inhomogeneities in walls on the external gamma doses in rooms.
United Kingdom.
Feher, I, Andrasi, A, Koblinger, L, Zombori, P, and Szabo, P P.
1984.
"Effects of activity inhomogeneities in walls on the external gamma doses in rooms."
United Kingdom.
@misc{etde_6216935,
title = {Effects of activity inhomogeneities in walls on the external gamma doses in rooms}
author = {Feher, I, Andrasi, A, Koblinger, L, Zombori, P, and Szabo, P P}
abstractNote = {The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.}
journal = []
volume = {7:1-4}
place = {United Kingdom}
year = {1984}
month = {Jan}
}
title = {Effects of activity inhomogeneities in walls on the external gamma doses in rooms}
author = {Feher, I, Andrasi, A, Koblinger, L, Zombori, P, and Szabo, P P}
abstractNote = {The effects of activity inhomogeneities in the walls of a room on the free-in-air and spherical phantom doses are investigated. Calculations and measurements are carried out in a room where the ratios of the activity concentrations in the upper layer of the ceiling and floor are as large as 20 and 6, for the Ra and Th chains, respectively.}
journal = []
volume = {7:1-4}
place = {United Kingdom}
year = {1984}
month = {Jan}
}