Sterilization of the artificial blood circulation apparatus with ozone

Journal Article:

Abstract

Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.
Publication Date:
Jan 01, 1982
Product Type:
Journal Article
Reference Number:
EDB-83-078567
Resource Relation:
Journal Name: Med. Tekh.; (USSR); Journal Volume: 5
Subject:
54 ENVIRONMENTAL SCIENCES; 63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.; MECHANICAL HEART; STERILIZATION; BIOLOGICAL EFFECTS; BLOOD CIRCULATION; MICROORGANISMS; OZONE; MEDICAL SUPPLIES; PROSTHESES; 500600* - Environment, Atmospheric- Regulations- (-1989); 560302 - Chemicals Metabolism & Toxicology- Microorganisms- (-1987)
OSTI ID:
6188984
Country of Origin:
USSR
Language:
Russian
Other Identifying Numbers:
Journal ID: CODEN: MEDTB
Submitting Site:
HEDB
Size:
Pages: 47-49
Announcement Date:

Journal Article:

Citation Formats

Pisarevskii, A A, Korukhov, N I.U., Brazhnikov, E M, Konstantinova, M L, and Razumovskii, S D. Sterilization of the artificial blood circulation apparatus with ozone. USSR: N. p., 1982. Web.
Pisarevskii, A A, Korukhov, N I.U., Brazhnikov, E M, Konstantinova, M L, & Razumovskii, S D. Sterilization of the artificial blood circulation apparatus with ozone. USSR.
Pisarevskii, A A, Korukhov, N I.U., Brazhnikov, E M, Konstantinova, M L, and Razumovskii, S D. 1982. "Sterilization of the artificial blood circulation apparatus with ozone." USSR.
@misc{etde_6188984,
title = {Sterilization of the artificial blood circulation apparatus with ozone}
author = {Pisarevskii, A A, Korukhov, N I.U., Brazhnikov, E M, Konstantinova, M L, and Razumovskii, S D}
abstractNote = {Presented in this paper is the sterilization method of the assisted circulation unit. The method has been approved by stand testing and then applied for sterilizing the unit Ae, yeK-5 m when experimental implanting artificial heart. According to the method, ozone in concentration of 5 x 10(-3) moles/1 and with flow rate of 0,5 1/min is passed through an internal circuit of the unit during I h and 15 min. Control wash-out samples from lines have demonstrated complete sterility of the internal circuit. The method makes the sterilization process of such units much easier and may be recommended for clinical application.}
journal = {Med. Tekh.; (USSR)}
volume = {5}
journal type = {AC}
place = {USSR}
year = {1982}
month = {Jan}
}