Abstract
The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.
Kral, P
[1]
- Nuclear Research Inst. Rez (Switzerland)
Citation Formats
Kral, P.
Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP.
Finland: N. p.,
1995.
Web.
Kral, P.
Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP.
Finland.
Kral, P.
1995.
"Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP."
Finland.
@misc{etde_614752,
title = {Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP}
author = {Kral, P}
abstractNote = {The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.}
place = {Finland}
year = {1995}
month = {Dec}
}
title = {Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP}
author = {Kral, P}
abstractNote = {The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.}
place = {Finland}
year = {1995}
month = {Dec}
}