Abstract
Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.
Beliaev, J;
Trunov, N;
Tschekin, I;
[1]
Luther, W;
[2]
Spolitak, S
[3]
- OKB Gidropress (Russian Federation)
- GRS Garching (Germany)
- RNC-KI (Russian Federation)
Citation Formats
Beliaev, J, Trunov, N, Tschekin, I, Luther, W, and Spolitak, S.
Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations.
Finland: N. p.,
1995.
Web.
Beliaev, J, Trunov, N, Tschekin, I, Luther, W, & Spolitak, S.
Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations.
Finland.
Beliaev, J, Trunov, N, Tschekin, I, Luther, W, and Spolitak, S.
1995.
"Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations."
Finland.
@misc{etde_614738,
title = {Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations}
author = {Beliaev, J, Trunov, N, Tschekin, I, Luther, W, and Spolitak, S}
abstractNote = {Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.}
place = {Finland}
year = {1995}
month = {Dec}
}
title = {Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations}
author = {Beliaev, J, Trunov, N, Tschekin, I, Luther, W, and Spolitak, S}
abstractNote = {Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.}
place = {Finland}
year = {1995}
month = {Dec}
}