Abstract
The task of the team was to create a fallout map of {sup 137}Cs on a specified area in Padasjoki Auttoinen village. The team used AB-420 helicopter of the Finnish Frontier Guard. The team had two measuring systems: HPGe system (relative efficiency 18%) and NaI system (5`x5`). Both systems produced similar maps. The average {sup 137}Cs fallout within the area (lakes and ponds included) was 88 kBq m{sup -2,} the maximum value being 161 kBq m{sup -2}. In an emergency the HPGe is superior to NaI because of its better energy resolution, giving possibility to obtain nuclide-specific results. (au).
Nikkinen, M;
Aarnio, P;
[1]
Honkamaa, T;
Tiilikainen, H
[2]
- Helsinki Univ. of Technology, Espoo (Finland)
- Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland)
Citation Formats
Nikkinen, M, Aarnio, P, Honkamaa, T, and Tiilikainen, H.
Airborne fallout mapping of {sup 137}Cs - STUK/HUT team.
Denmark: N. p.,
1997.
Web.
Nikkinen, M, Aarnio, P, Honkamaa, T, & Tiilikainen, H.
Airborne fallout mapping of {sup 137}Cs - STUK/HUT team.
Denmark.
Nikkinen, M, Aarnio, P, Honkamaa, T, and Tiilikainen, H.
1997.
"Airborne fallout mapping of {sup 137}Cs - STUK/HUT team."
Denmark.
@misc{etde_606700,
title = {Airborne fallout mapping of {sup 137}Cs - STUK/HUT team}
author = {Nikkinen, M, Aarnio, P, Honkamaa, T, and Tiilikainen, H}
abstractNote = {The task of the team was to create a fallout map of {sup 137}Cs on a specified area in Padasjoki Auttoinen village. The team used AB-420 helicopter of the Finnish Frontier Guard. The team had two measuring systems: HPGe system (relative efficiency 18%) and NaI system (5`x5`). Both systems produced similar maps. The average {sup 137}Cs fallout within the area (lakes and ponds included) was 88 kBq m{sup -2,} the maximum value being 161 kBq m{sup -2}. In an emergency the HPGe is superior to NaI because of its better energy resolution, giving possibility to obtain nuclide-specific results. (au).}
place = {Denmark}
year = {1997}
month = {Dec}
}
title = {Airborne fallout mapping of {sup 137}Cs - STUK/HUT team}
author = {Nikkinen, M, Aarnio, P, Honkamaa, T, and Tiilikainen, H}
abstractNote = {The task of the team was to create a fallout map of {sup 137}Cs on a specified area in Padasjoki Auttoinen village. The team used AB-420 helicopter of the Finnish Frontier Guard. The team had two measuring systems: HPGe system (relative efficiency 18%) and NaI system (5`x5`). Both systems produced similar maps. The average {sup 137}Cs fallout within the area (lakes and ponds included) was 88 kBq m{sup -2,} the maximum value being 161 kBq m{sup -2}. In an emergency the HPGe is superior to NaI because of its better energy resolution, giving possibility to obtain nuclide-specific results. (au).}
place = {Denmark}
year = {1997}
month = {Dec}
}