You need JavaScript to view this

About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators

Abstract

The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.
Authors:
Mitioukov, V; Mitrioukhine, A; [1]  Korteniemi, V [2] 
  1. St. Petersburg State Technical Univ. (Russian Federation)
  2. Lappeenranta Univ. of Technology (Finland)
Publication Date:
Dec 31, 1997
Product Type:
Conference
Report Number:
LTKK-TJ-67; CONF-9703151-
Reference Number:
SCA: 210200; PA: AIX-29:024686; EDB-98:048824; SN: 98001958627
Resource Relation:
Conference: 4. international seminar on horizontal steam generators, Lappeenranta (Finland), 11-13 Mar 1997; Other Information: DN: 4 refs.; PBD: 1997; Related Information: Is Part Of Fourth international seminar on horizontal steam generators; Tuomisto, H. [ed.] [IVO Group, Vantaa (Finland)]; Purhonen, H. [ed.] [VTT, Espoo (Finland)]; Kouhia, V. [ed.] [Lappeenranta Univ. of Technology (Finland)]; PB: 305 p.
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; NATURAL CONVECTION; REACTOR SAFETY EXPERIMENTS; STEAM GENERATORS; STRATIFICATION; TEST FACILITIES; WWER TYPE REACTORS
OSTI ID:
605581
Research Organizations:
Lappeenranta Univ. of Technology (Finland).
Country of Origin:
Finland
Language:
English
Other Identifying Numbers:
Other: ON: DE98621567; ISBN 951-764-189-3; TRN: FI9800035024686
Availability:
INIS; OSTI as DE98621567
Submitting Site:
FIN
Size:
pp. 163-168
Announcement Date:

Citation Formats

Mitioukov, V, Mitrioukhine, A, and Korteniemi, V. About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators. Finland: N. p., 1997. Web.
Mitioukov, V, Mitrioukhine, A, & Korteniemi, V. About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators. Finland.
Mitioukov, V, Mitrioukhine, A, and Korteniemi, V. 1997. "About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators." Finland.
@misc{etde_605581,
title = {About technical possibility to use VEERA facility for investigation of coolant stratification phenomenon in horizontal steam generators}
author = {Mitioukov, V, Mitrioukhine, A, and Korteniemi, V}
abstractNote = {The presentation gives a brief insight on possibility of using the VEERA facility in studying the stratification phenomenon. The idea for such experiments is to use the facility upper plenum part to simulate the conditions in upper part of horizontal steam generator hot collector. The upper part of steam generator hot collector is one of the locations where the stratification can take part during natural circulation mode. 4 refs.}
place = {Finland}
year = {1997}
month = {Dec}
}