The presentation summarises the results of best estimate calculations carried out with reference to the WWER-1000 Nuclear Power Plant, utilizing a qualified nodalization set-up for the Relap5/Mod3.2 code. The nodalization development has been based on the data of the Kozloduy Bulgarian Plant. The geometry of the steam generator imposed drastic changes in noding philosophy with respect to what is suitable for the U-tubes steam generators. For the secondary side a symmetry axis was chosen to separate (in the nodalization) the hot and the cold sides of the tubes. In this way the secondary side of the steam generators was divided into three zones: (a) the hot zone including the hot collector and the hot l/2 parts of the tubes; (b) the cold zone including the cold collector and the cold 1/2 parts of the tubes; (c) the downcomer region, where down flow is assumed. As a consequence of above in the primary side more nodes are placed on the hot side of the tubes. Steady state and transient qualification has been achieved, considering the criteria proposed at the University of Pisa, utilizing plant transient data from the Kozloduy and the Ukrainian Zaporosche Plants. The results of the application of the  More>>
Authors:
D`Auria, F; Galassi, G M; [1]  Frogheri, M [2] 
  1. Univ. of Pisa (Italy)
  2. Univ. of Genova (Italy)
Publication Date:
Dec 31, 1997
Product Type:
Conference
Report Number:
LTKK-TJ-67; CONF-9703151-
Reference Number:
SCA: 210200; PA: AIX-29:024678; EDB-98:048726; SN: 98001958619
Resource Relation:
Conference: 4. international seminar on horizontal steam generators, Lappeenranta (Finland), 11-13 Mar 1997; Other Information: DN: 23 refs.; PBD: 1997; Related Information: Is Part Of Fourth international seminar on horizontal steam generators; Tuomisto, H. [ed.] [IVO Group, Vantaa (Finland)]; Purhonen, H. [ed.] [VTT, Espoo (Finland)]; Kouhia, V. [ed.] [Lappeenranta Univ. of Technology (Finland)]; PB: 305 p.
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; COMPUTERIZED SIMULATION; LOSS OF COOLANT; NODAL EXPANSION METHOD; R CODES; REACTOR SAFETY; STEAM GENERATORS; TRANSIENTS; WWER TYPE REACTORS
OSTI ID:
605573
Research Organizations:
Lappeenranta Univ. of Technology (Finland).
Country of Origin:
Finland
Language:
English
Other Identifying Numbers:
Other: ON: DE98621567; ISBN 951-764-189-3; TRN: FI9800027024678
Availability:
INIS; OSTI as DE98621567
Submitting Site:
FIN
Size:
pp. 54-71
Announcement Date:
Jun 10, 1998

Citation Formats

D`Auria, F, Galassi, G M, and Frogheri, M. Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code. Finland: N. p., 1997. Web.
D`Auria, F, Galassi, G M, & Frogheri, M. Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code. Finland.
D`Auria, F, Galassi, G M, and Frogheri, M. 1997. "Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code." Finland.
@misc{etde_605573,
title = {Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code}
author = {D`Auria, F, Galassi, G M, and Frogheri, M}
abstractNote = {The presentation summarises the results of best estimate calculations carried out with reference to the WWER-1000 Nuclear Power Plant, utilizing a qualified nodalization set-up for the Relap5/Mod3.2 code. The nodalization development has been based on the data of the Kozloduy Bulgarian Plant. The geometry of the steam generator imposed drastic changes in noding philosophy with respect to what is suitable for the U-tubes steam generators. For the secondary side a symmetry axis was chosen to separate (in the nodalization) the hot and the cold sides of the tubes. In this way the secondary side of the steam generators was divided into three zones: (a) the hot zone including the hot collector and the hot l/2 parts of the tubes; (b) the cold zone including the cold collector and the cold 1/2 parts of the tubes; (c) the downcomer region, where down flow is assumed. As a consequence of above in the primary side more nodes are placed on the hot side of the tubes. Steady state and transient qualification has been achieved, considering the criteria proposed at the University of Pisa, utilizing plant transient data from the Kozloduy and the Ukrainian Zaporosche Plants. The results of the application of the qualified WWER-1000 Relap5/Mod3.2 nodalization to various transients including large break LOCA, small break LOCA and steam generator tube rupture, together with a sensitivity analysis on the steam generators, are reported in the presentation. Emphasis is given to the prediction of the steam generators performances. 23 refs.}
place = {Finland}
year = {1997}
month = {Dec}
}