You need JavaScript to view this

Cherenkov particle identifier for relativistic heavy ions

Abstract

A total internal reflection Cherenkov detector is described. A figure of merit of 84Z/sup 2/sin/sup 2/theta photoelectrons/cm has been measured and the application of the device to charge and velocity measurements of relativistic heavy ions has been tested. We have achieved a charge resolution of ..delta..Zsub(rms)=0.15e for Z=20 with a 3 mm thick glass detector and a velocity resolution of ..delta beta..sub(rms)=2x10/sup -4/ at ..beta..=0.93 and Z=26 with a 6 mm thick fused silica detector. Combining charge and velocity measurements with a magnetic rigidity selection, we have achieved an isotopic mass resolution of ..delta..Msub(rms)=0.1 u with a 2 mm thick fused silica detector for 20<40. (orig.).
Publication Date:
Dec 01, 1985
Product Type:
Journal Article
Reference Number:
NLN-86-000946; EDB-86-053926
Resource Relation:
Journal Name: Nucl. Instrum. Methods Phys. Res.; (Netherlands); Journal Volume: 241:2/3
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; CHERENKOV COUNTERS; ION DETECTION; MASS SPECTROSCOPY; ARGON ISOTOPES; MASS RESOLUTION; MASS SPECTRA; PARTICLE IDENTIFICATION; RELATIVISTIC RANGE; SCATTERPLOTS; CHARGED PARTICLE DETECTION; DETECTION; DIAGRAMS; ENERGY RANGE; ISOTOPES; MEASURING INSTRUMENTS; RADIATION DETECTION; RADIATION DETECTORS; RESOLUTION; SPECTRA; SPECTROSCOPY; 440103* - Radiation Instrumentation- Nuclear Spectroscopic Instrumentation
OSTI ID:
6043075
Research Organizations:
California Univ., Berkeley, USA. Div. of Nuclear Science; California Univ., Berkeley, USA. Space Sciences Lab.
Country of Origin:
Netherlands
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: NIMRD
Submitting Site:
NLN
Size:
Pages: 491-502
Announcement Date:
Mar 01, 1986

Citation Formats

Dufour, J P, Olson, D L, Baumgartner, M, Girard, J G, Lindstrom, P J, Greiner, D E, Symons, T J.M., and Crawford, H J. Cherenkov particle identifier for relativistic heavy ions. Netherlands: N. p., 1985. Web. doi:10.1016/0168-9002(85)90602-3.
Dufour, J P, Olson, D L, Baumgartner, M, Girard, J G, Lindstrom, P J, Greiner, D E, Symons, T J.M., &amp; Crawford, H J. Cherenkov particle identifier for relativistic heavy ions. Netherlands. https://doi.org/10.1016/0168-9002(85)90602-3
Dufour, J P, Olson, D L, Baumgartner, M, Girard, J G, Lindstrom, P J, Greiner, D E, Symons, T J.M., and Crawford, H J. 1985. "Cherenkov particle identifier for relativistic heavy ions." Netherlands. https://doi.org/10.1016/0168-9002(85)90602-3.
@misc{etde_6043075,
title = {Cherenkov particle identifier for relativistic heavy ions}
author = {Dufour, J P, Olson, D L, Baumgartner, M, Girard, J G, Lindstrom, P J, Greiner, D E, Symons, T J.M., and Crawford, H J}
abstractNote = {A total internal reflection Cherenkov detector is described. A figure of merit of 84Z/sup 2/sin/sup 2/theta photoelectrons/cm has been measured and the application of the device to charge and velocity measurements of relativistic heavy ions has been tested. We have achieved a charge resolution of ..delta..Zsub(rms)=0.15e for Z=20 with a 3 mm thick glass detector and a velocity resolution of ..delta beta..sub(rms)=2x10/sup -4/ at ..beta..=0.93 and Z=26 with a 6 mm thick fused silica detector. Combining charge and velocity measurements with a magnetic rigidity selection, we have achieved an isotopic mass resolution of ..delta..Msub(rms)=0.1 u with a 2 mm thick fused silica detector for 20<40. (orig.).}
doi = {10.1016/0168-9002(85)90602-3}
journal = []
volume = {241:2/3}
journal type = {AC}
place = {Netherlands}
year = {1985}
month = {Dec}
}