You need JavaScript to view this

Estimation of intergrity of cast-iron cask against impact due to free drop test, (3); Verification of brittle failure design criterion

Abstract

As a cask material, ductile cast iron has the potential to fail in a brittle manner under certain temperature and load conditions. The design criterion of ductile cast iron casks against brittle failure due to a drop test, has been proposed by CRIEPI. In this report, in order to verify the proposed design criterion, a 9m drop test using a full scale cask with an artificial flaw of 83.5mm in depth located at the most critical location was carried out at the low temperature of -40degC. As the test results, no crack propagation from the artificial flaw was observed under the severe condition such that the safety factor (1.78) calculated from the design criterion was below the value (2) in the criterion, thus confirming that the proposed brittle failure design criterion is applicable to evaluate the integrity of ductile cast iron cask against brittle failure due to a drop test. (author).
Authors:
Shirai, Takaharu; Kato, Osamu; Ito, Chihiro; Shimazaki, Katsunori; [1]  Saegusa, Toshiari
  1. Central Research Inst. of Electric Power Industry, Abiko, Chiba (Japan). Abiko Research Lab.
Publication Date:
Apr 01, 1990
Product Type:
Journal Article
Reference Number:
JPN-91-002281; EDB-91-038100
Resource Relation:
Journal Name: Denryoku Chuo Kenkyusho Hokoku (Technical Report of the Central Research Institute of Electric Power Industry); (Japan); Journal Volume: U90001
Subject:
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; CASKS; IMPACT TESTS; BRITTLENESS; CAST IRON; D CODES; DESTRUCTIVE TESTING; EXPERIMENTAL DATA; FRACTURE MECHANICS; IMPACT SHOCK; PLANNING; RELIABILITY; RISK ASSESSMENT; ALLOYS; CARBIDES; CARBON COMPOUNDS; COMPUTER CODES; CONTAINERS; DATA; INFORMATION; IRON ALLOYS; IRON BASE ALLOYS; IRON CARBIDES; IRON COMPOUNDS; MATERIALS TESTING; MECHANICAL PROPERTIES; MECHANICAL TESTS; MECHANICS; NUMERICAL DATA; TESTING; TRANSITION ELEMENT COMPOUNDS; 050900* - Nuclear Fuels- Transport, Handling, & Storage
OSTI ID:
6017814
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Journal ID: CODEN: DCKHD
Submitting Site:
JPN
Size:
Pages: 1-4, 1-41
Announcement Date:
Apr 01, 1991

Citation Formats

Shirai, Takaharu, Kato, Osamu, Ito, Chihiro, Shimazaki, Katsunori, and Saegusa, Toshiari. Estimation of intergrity of cast-iron cask against impact due to free drop test, (3); Verification of brittle failure design criterion. Japan: N. p., 1990. Web.
Shirai, Takaharu, Kato, Osamu, Ito, Chihiro, Shimazaki, Katsunori, & Saegusa, Toshiari. Estimation of intergrity of cast-iron cask against impact due to free drop test, (3); Verification of brittle failure design criterion. Japan.
Shirai, Takaharu, Kato, Osamu, Ito, Chihiro, Shimazaki, Katsunori, and Saegusa, Toshiari. 1990. "Estimation of intergrity of cast-iron cask against impact due to free drop test, (3); Verification of brittle failure design criterion." Japan.
@misc{etde_6017814,
title = {Estimation of intergrity of cast-iron cask against impact due to free drop test, (3); Verification of brittle failure design criterion}
author = {Shirai, Takaharu, Kato, Osamu, Ito, Chihiro, Shimazaki, Katsunori, and Saegusa, Toshiari}
abstractNote = {As a cask material, ductile cast iron has the potential to fail in a brittle manner under certain temperature and load conditions. The design criterion of ductile cast iron casks against brittle failure due to a drop test, has been proposed by CRIEPI. In this report, in order to verify the proposed design criterion, a 9m drop test using a full scale cask with an artificial flaw of 83.5mm in depth located at the most critical location was carried out at the low temperature of -40degC. As the test results, no crack propagation from the artificial flaw was observed under the severe condition such that the safety factor (1.78) calculated from the design criterion was below the value (2) in the criterion, thus confirming that the proposed brittle failure design criterion is applicable to evaluate the integrity of ductile cast iron cask against brittle failure due to a drop test. (author).}
journal = []
volume = {U90001}
journal type = {AC}
place = {Japan}
year = {1990}
month = {Apr}
}