Abstract
A study on safety measures of LMR coolant showed the results as follows: 1. Sodium fire characteristics. A. Sodium pool temp., gas temp., oxygen concentration calculated by flame combustion model were generally higher than those calculated by surface combustion model. B. Basic and detail designs for medium sodium fire test facility were carried out and medium sodium fire test facility was constructed. 2. Sodium/Cover gas purification technology. A. Construction and operation of calibration loop. B. Purification analysis and conceptual design of the packing for a cold trap. 3. Analysis of sodium-water reaction characteristics. We have investigated the characteristics analysis for micro and small leaks phenomena, development of the computer code for analysis of initial and quasi steady-state spike pressures to analyze large leak accident. Also, water mock-up test facility for the analysis of large leak accident phenomena was designed and manufactured. 4. Development of water leak detection technology. Detection signals were appeared when the hydrogen detector is operated to Ar-H{sub 2} gas system. The technology for the passive acoustic detection with respect to large leakage of water into sodium media was reviewed. And water mock-up test equipment and instrument system were designed and constructed. (author). 19 refs., 45 tabs., 52
More>>
Citation Formats
Hwang, Sung Tai, Choi, Y D, Choi, J H, Kim, T J, Jeong, K C, Kwon, S W, Kim, B H, Jeong, J Y, Park, J H, Kim, K R, and Jo, B R.
A study on safety measure of LMR coolant.
Korea, Republic of: N. p.,
1997.
Web.
Hwang, Sung Tai, Choi, Y D, Choi, J H, Kim, T J, Jeong, K C, Kwon, S W, Kim, B H, Jeong, J Y, Park, J H, Kim, K R, & Jo, B R.
A study on safety measure of LMR coolant.
Korea, Republic of.
Hwang, Sung Tai, Choi, Y D, Choi, J H, Kim, T J, Jeong, K C, Kwon, S W, Kim, B H, Jeong, J Y, Park, J H, Kim, K R, and Jo, B R.
1997.
"A study on safety measure of LMR coolant."
Korea, Republic of.
@misc{etde_595306,
title = {A study on safety measure of LMR coolant}
author = {Hwang, Sung Tai, Choi, Y D, Choi, J H, Kim, T J, Jeong, K C, Kwon, S W, Kim, B H, Jeong, J Y, Park, J H, Kim, K R, and Jo, B R}
abstractNote = {A study on safety measures of LMR coolant showed the results as follows: 1. Sodium fire characteristics. A. Sodium pool temp., gas temp., oxygen concentration calculated by flame combustion model were generally higher than those calculated by surface combustion model. B. Basic and detail designs for medium sodium fire test facility were carried out and medium sodium fire test facility was constructed. 2. Sodium/Cover gas purification technology. A. Construction and operation of calibration loop. B. Purification analysis and conceptual design of the packing for a cold trap. 3. Analysis of sodium-water reaction characteristics. We have investigated the characteristics analysis for micro and small leaks phenomena, development of the computer code for analysis of initial and quasi steady-state spike pressures to analyze large leak accident. Also, water mock-up test facility for the analysis of large leak accident phenomena was designed and manufactured. 4. Development of water leak detection technology. Detection signals were appeared when the hydrogen detector is operated to Ar-H{sub 2} gas system. The technology for the passive acoustic detection with respect to large leakage of water into sodium media was reviewed. And water mock-up test equipment and instrument system were designed and constructed. (author). 19 refs., 45 tabs., 52 figs.}
place = {Korea, Republic of}
year = {1997}
month = {Aug}
}
title = {A study on safety measure of LMR coolant}
author = {Hwang, Sung Tai, Choi, Y D, Choi, J H, Kim, T J, Jeong, K C, Kwon, S W, Kim, B H, Jeong, J Y, Park, J H, Kim, K R, and Jo, B R}
abstractNote = {A study on safety measures of LMR coolant showed the results as follows: 1. Sodium fire characteristics. A. Sodium pool temp., gas temp., oxygen concentration calculated by flame combustion model were generally higher than those calculated by surface combustion model. B. Basic and detail designs for medium sodium fire test facility were carried out and medium sodium fire test facility was constructed. 2. Sodium/Cover gas purification technology. A. Construction and operation of calibration loop. B. Purification analysis and conceptual design of the packing for a cold trap. 3. Analysis of sodium-water reaction characteristics. We have investigated the characteristics analysis for micro and small leaks phenomena, development of the computer code for analysis of initial and quasi steady-state spike pressures to analyze large leak accident. Also, water mock-up test facility for the analysis of large leak accident phenomena was designed and manufactured. 4. Development of water leak detection technology. Detection signals were appeared when the hydrogen detector is operated to Ar-H{sub 2} gas system. The technology for the passive acoustic detection with respect to large leakage of water into sodium media was reviewed. And water mock-up test equipment and instrument system were designed and constructed. (author). 19 refs., 45 tabs., 52 figs.}
place = {Korea, Republic of}
year = {1997}
month = {Aug}
}