Sizing of ion exchange column for PHT purification system of 500 MWe Indian PHWR

Abstract

Strict chemistry control is required on the heavy water coolant in the primary loop of the PHWR to ensure stability of oxide corrosion film and to prevent corrosion build up on the surfaces. This is achieved by maintaining PD value of PHT coolant at about 10.45 and sp. conductivity between 20 to 40 mhos/cm by ion exchange column and filtration of coolant. This paper deals with the sizing and selection of bed height of ninth column from different methods. (author). 7 refs., 6 figs.
Authors:
Goswami, S; Sharma, A K; Bapat, C N; Sharma, V K [1] 
  1. Nuclear Power Corporation, Bhabha Atomic Research Centre, Mumbai (India)
Publication Date:
Jun 01, 1994
Product Type:
Conference
Report Number:
CONF-9406439-
Reference Number:
SCA: 210400; PA: AIX-29:018184; EDB-98:048897; SN: 98001952242
Resource Relation:
Conference: ACE-94: advances in chemical engineering in nuclear and process industries, Mumbai (India), 9-11 Jun 1994; Other Information: DN: 7 refs., 6 figs.; PBD: Jun 1994; Related Information: Is Part Of Advances in chemical engineering in nuclear and process industries; PB: 628 p.
Subject:
21 NUCLEAR POWER REACTORS AND ASSOCIATED PLANTS; COOLANT CLEANUP SYSTEMS; CORROSION PROTECTION; DIFFUSION; FLOWSHEETS; HEAVY WATER; ION EXCHANGE; PHWR TYPE REACTORS; POWER RANGE 100-1000 MW; PRIMARY COOLANT CIRCUITS; PURIFICATION
OSTI ID:
592041
Research Organizations:
Board of Research in Nuclear Sciences, Department of Atomic Energy, Mumbai (India).
Country of Origin:
India
Language:
English
Other Identifying Numbers:
TRN: IN9800297018184
Submitting Site:
INIS
Size:
pp. 589-599
Announcement Date:
Jan 23, 2004

Citation Formats

Goswami, S, Sharma, A K, Bapat, C N, and Sharma, V K. Sizing of ion exchange column for PHT purification system of 500 MWe Indian PHWR. India: N. p., 1994. Web.
Goswami, S, Sharma, A K, Bapat, C N, & Sharma, V K. Sizing of ion exchange column for PHT purification system of 500 MWe Indian PHWR. India.
Goswami, S, Sharma, A K, Bapat, C N, and Sharma, V K. 1994. "Sizing of ion exchange column for PHT purification system of 500 MWe Indian PHWR." India.
@misc{etde_592041,
title = {Sizing of ion exchange column for PHT purification system of 500 MWe Indian PHWR}
author = {Goswami, S, Sharma, A K, Bapat, C N, and Sharma, V K}
abstractNote = {Strict chemistry control is required on the heavy water coolant in the primary loop of the PHWR to ensure stability of oxide corrosion film and to prevent corrosion build up on the surfaces. This is achieved by maintaining PD value of PHT coolant at about 10.45 and sp. conductivity between 20 to 40 mhos/cm by ion exchange column and filtration of coolant. This paper deals with the sizing and selection of bed height of ninth column from different methods. (author). 7 refs., 6 figs.}
place = {India}
year = {1994}
month = {Jun}
}