Abstract
In situ calibration curves were installed for the soil surface using different models of depth neutron probes and different adaptors. depth beutron probe readings increased with increasing the number of teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis decreased with increasing of teflon plastics blocks deposited on the soil surface in all sites. The least exposure was with depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth probe with a block laid on the surface, without a danger of receiving the thresgold of radiation dose. (author). 10 Refs., 2 Figs., 8 Tabs.
Arslan, A;
Razzouk, A K;
Al-Ain, F
[1]
- Atomic Energy commission , Damascus (Syrian Arab Republic). Dept of Radiation Agriculture
Citation Formats
Arslan, A, Razzouk, A K, and Al-Ain, F.
A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users.
Syrian Arab Republic: N. p.,
1996.
Web.
Arslan, A, Razzouk, A K, & Al-Ain, F.
A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users.
Syrian Arab Republic.
Arslan, A, Razzouk, A K, and Al-Ain, F.
1996.
"A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users."
Syrian Arab Republic.
@misc{etde_591312,
title = {A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users}
author = {Arslan, A, Razzouk, A K, and Al-Ain, F}
abstractNote = {In situ calibration curves were installed for the soil surface using different models of depth neutron probes and different adaptors. depth beutron probe readings increased with increasing the number of teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis decreased with increasing of teflon plastics blocks deposited on the soil surface in all sites. The least exposure was with depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth probe with a block laid on the surface, without a danger of receiving the thresgold of radiation dose. (author). 10 Refs., 2 Figs., 8 Tabs.}
place = {Syrian Arab Republic}
year = {1996}
month = {Aug}
}
title = {A comparison of different neutron probes calibration method for the soil surface and their radiation effect on the users}
author = {Arslan, A, Razzouk, A K, and Al-Ain, F}
abstractNote = {In situ calibration curves were installed for the soil surface using different models of depth neutron probes and different adaptors. depth beutron probe readings increased with increasing the number of teflon plastic blocks deposited on the soil surface. The intercept of the straight line regression analysis decreased with increasing of teflon plastics blocks deposited on the soil surface in all sites. The least exposure was with depth probe with surface reflectors. This study proves the possibility of measuring the moisture content of the soil surface by using a depth probe with a block laid on the surface, without a danger of receiving the thresgold of radiation dose. (author). 10 Refs., 2 Figs., 8 Tabs.}
place = {Syrian Arab Republic}
year = {1996}
month = {Aug}
}