You need JavaScript to view this

Ion beam pulse radiolysis system at HIMAC

Abstract

An ion beam pulse radiolysis system has been constructed at HIMAC facility. Ion beam of 24MeV He{sup 2+} with the duration longer than 1 {mu}s is available for irradiation. Three kinds of aqueous solutions, (C{sub 6}H{sub 5}){sub 2}CO, NaHCO{sub 3}, and KSCN, were irradiated and the absorption signals corresponding to (C{sub 6}H{sub 5}){sub 2}CO{sup -}, CO{sub 3}{sup -}, and (SCN){sub 2}{sup -} respectively were observed. Ghost signals which interfere with the measurement are also discussed. (author)
Authors:
Chitose, N; Katsumura, Y; Domae, M; Ishigure, K; [1]  Murakami, T
  1. Tokyo Univ. (Japan)
Publication Date:
Mar 01, 1997
Product Type:
Conference
Report Number:
JAERI-Conf-97-003; CONF-9603254-
Reference Number:
SCA: 430303; PA: JPN-97:010140; EDB-98:039921; SN: 98001890483
Resource Relation:
Conference: 7. international symposium on advanced nuclear energy research, Takasaki (Japan), 18-20 Mar 1996; Other Information: PBD: Mar 1997; Related Information: Is Part Of Recent progress in accelerator beam application. Proceedings of the 7th international symposium on advanced nuclear energy research; PB: 553 p.
Subject:
43 PARTICLE ACCELERATORS; ION BEAMS; RADIOLYSIS; PULSE TECHNIQUES; HIMAC ACCELERATOR; ACCELERATOR FACILITIES; IRRADIATION; AQUEOUS SOLUTIONS; HELIUM IONS; LET; BACKGROUND NOISE
OSTI ID:
588378
Research Organizations:
Japan Atomic Energy Research Inst., Tokyo (Japan)
Country of Origin:
Japan
Language:
English
Other Identifying Numbers:
Other: ON: DE97764433; TRN: JP9710140
Availability:
OSTI as DE97764433
Submitting Site:
JPN
Size:
pp. 303-307
Announcement Date:

Citation Formats

Chitose, N, Katsumura, Y, Domae, M, Ishigure, K, and Murakami, T. Ion beam pulse radiolysis system at HIMAC. Japan: N. p., 1997. Web.
Chitose, N, Katsumura, Y, Domae, M, Ishigure, K, & Murakami, T. Ion beam pulse radiolysis system at HIMAC. Japan.
Chitose, N, Katsumura, Y, Domae, M, Ishigure, K, and Murakami, T. 1997. "Ion beam pulse radiolysis system at HIMAC." Japan.
@misc{etde_588378,
title = {Ion beam pulse radiolysis system at HIMAC}
author = {Chitose, N, Katsumura, Y, Domae, M, Ishigure, K, and Murakami, T}
abstractNote = {An ion beam pulse radiolysis system has been constructed at HIMAC facility. Ion beam of 24MeV He{sup 2+} with the duration longer than 1 {mu}s is available for irradiation. Three kinds of aqueous solutions, (C{sub 6}H{sub 5}){sub 2}CO, NaHCO{sub 3}, and KSCN, were irradiated and the absorption signals corresponding to (C{sub 6}H{sub 5}){sub 2}CO{sup -}, CO{sub 3}{sup -}, and (SCN){sub 2}{sup -} respectively were observed. Ghost signals which interfere with the measurement are also discussed. (author)}
place = {Japan}
year = {1997}
month = {Mar}
}