You need JavaScript to view this

Present status of tandem accelerator in Tsukuba University

Abstract

The tandem accelerator in Tsukuba University, 12UD Peletron, has continued the operation for 21 years, and the total operation time became 61,822 hours as of the end of March, 1996. In this paper, the state of operation of the tandem accelerator in 1995 and the state of use classified by experimental fields are reported. As for the improvement of peripheral equipment, the renewal of the radiation monitoring system and the new installation of the going-in and out control system for radiation control zones were carried out. In fiscal year 1995, the operation time of the accelerator was 3,966 hours, and ion acceleration time was 3,427 hours or 86%. The renewal and improvement of the accelerator system that had been begun in fiscal year 1989 was completed. Also the operation at highest accelerating voltage 12 MV was carried out for 7 hours. In March, the operation was not done because of the periodic inspection. The state of use of two ion sources for joint utilization is shown, and 20 kinds of ions were used. The state of joint utilization, the troubles and repair, and the renewal and new installation are reported. The plan of installing 1 MV TANDETRON is explained. (K.I.)
Authors:
Ishihara, Toyoyuki; Oshima, Hiroyuki; Ishii, Satoshi [1] 
  1. Tsukuba Univ., Ibaraki (Japan). Tandem Accelerator Center; and others
Publication Date:
Dec 01, 1996
Product Type:
Conference
Report Number:
INIS-JP-078; CONF-9607207-
Reference Number:
SCA: 430100; PA: JPN-98:001242; EDB-98:039823; SN: 98001918455
Resource Relation:
Conference: 9. workshop on tandem accelerators and peripheral techniques, Tokai (Japan), 4-5 Jul 1996; Other Information: PBD: Dec 1996; Related Information: Is Part Of Proceedings of 9th workshop on tandem accelerators and peripheral techniques; PB: 119 p.; Dai-9-kai tandemu kasokuki oyobi sono shuhengijutsu no kenkyukai hokokushu
Subject:
43 PARTICLE ACCELERATORS; TANDEM ELECTROSTATIC ACCELERATORS; ACCELERATOR FACILITIES; ION SOURCES; OPERATION; USES; RADIATION PROTECTION; MAINTENANCE
OSTI ID:
588091
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE98708353; TRN: JP9801242
Availability:
OSTI as DE98708353
Submitting Site:
JPN
Size:
pp. 1-5
Announcement Date:

Citation Formats

Ishihara, Toyoyuki, Oshima, Hiroyuki, and Ishii, Satoshi. Present status of tandem accelerator in Tsukuba University. Japan: N. p., 1996. Web.
Ishihara, Toyoyuki, Oshima, Hiroyuki, & Ishii, Satoshi. Present status of tandem accelerator in Tsukuba University. Japan.
Ishihara, Toyoyuki, Oshima, Hiroyuki, and Ishii, Satoshi. 1996. "Present status of tandem accelerator in Tsukuba University." Japan.
@misc{etde_588091,
title = {Present status of tandem accelerator in Tsukuba University}
author = {Ishihara, Toyoyuki, Oshima, Hiroyuki, and Ishii, Satoshi}
abstractNote = {The tandem accelerator in Tsukuba University, 12UD Peletron, has continued the operation for 21 years, and the total operation time became 61,822 hours as of the end of March, 1996. In this paper, the state of operation of the tandem accelerator in 1995 and the state of use classified by experimental fields are reported. As for the improvement of peripheral equipment, the renewal of the radiation monitoring system and the new installation of the going-in and out control system for radiation control zones were carried out. In fiscal year 1995, the operation time of the accelerator was 3,966 hours, and ion acceleration time was 3,427 hours or 86%. The renewal and improvement of the accelerator system that had been begun in fiscal year 1989 was completed. Also the operation at highest accelerating voltage 12 MV was carried out for 7 hours. In March, the operation was not done because of the periodic inspection. The state of use of two ion sources for joint utilization is shown, and 20 kinds of ions were used. The state of joint utilization, the troubles and repair, and the renewal and new installation are reported. The plan of installing 1 MV TANDETRON is explained. (K.I.)}
place = {Japan}
year = {1996}
month = {Dec}
}