Abstract
To investigate the effect of local irradiation on biological systems, an apparatus for penetration controlled irradiation with charged particles was set up. By comparison of ranges of 1.5 MeV/u He{sup 2+} between the theoretically calculated ranges and the practical ranges using RCD dosimeter, it was demonstrated that the range of particles could be controlled linearly by changing the distance from the beam window in the atmosphere to a target. In addition, the penetration controlled irradiation of tobacco pollen increased the frequency of `leaky pollen`. The increased frequency of the leaky pollen suggests that a damage in the pollen envelope would be induced at the range-end. (orig.)
Watanabe, Hiroshi;
[1]
Tanaka, Atsushi;
Tano, Shigemitsu;
[2]
Inoue, Masayoshi
[3]
- Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Dept. of Radiation Research for Environment and Resources
- Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Advanced Science Research Center
- Kyoto Prefectural Univ. (Japan). Faculty of Agriculture
Citation Formats
Watanabe, Hiroshi, Tanaka, Atsushi, Tano, Shigemitsu, and Inoue, Masayoshi.
Influence of penetration controlled irradiation with charged particles on tobacco pollen.
Germany: N. p.,
1997.
Web.
Watanabe, Hiroshi, Tanaka, Atsushi, Tano, Shigemitsu, & Inoue, Masayoshi.
Influence of penetration controlled irradiation with charged particles on tobacco pollen.
Germany.
Watanabe, Hiroshi, Tanaka, Atsushi, Tano, Shigemitsu, and Inoue, Masayoshi.
1997.
"Influence of penetration controlled irradiation with charged particles on tobacco pollen."
Germany.
@misc{etde_583911,
title = {Influence of penetration controlled irradiation with charged particles on tobacco pollen}
author = {Watanabe, Hiroshi, Tanaka, Atsushi, Tano, Shigemitsu, and Inoue, Masayoshi}
abstractNote = {To investigate the effect of local irradiation on biological systems, an apparatus for penetration controlled irradiation with charged particles was set up. By comparison of ranges of 1.5 MeV/u He{sup 2+} between the theoretically calculated ranges and the practical ranges using RCD dosimeter, it was demonstrated that the range of particles could be controlled linearly by changing the distance from the beam window in the atmosphere to a target. In addition, the penetration controlled irradiation of tobacco pollen increased the frequency of `leaky pollen`. The increased frequency of the leaky pollen suggests that a damage in the pollen envelope would be induced at the range-end. (orig.)}
place = {Germany}
year = {1997}
month = {Sep}
}
title = {Influence of penetration controlled irradiation with charged particles on tobacco pollen}
author = {Watanabe, Hiroshi, Tanaka, Atsushi, Tano, Shigemitsu, and Inoue, Masayoshi}
abstractNote = {To investigate the effect of local irradiation on biological systems, an apparatus for penetration controlled irradiation with charged particles was set up. By comparison of ranges of 1.5 MeV/u He{sup 2+} between the theoretically calculated ranges and the practical ranges using RCD dosimeter, it was demonstrated that the range of particles could be controlled linearly by changing the distance from the beam window in the atmosphere to a target. In addition, the penetration controlled irradiation of tobacco pollen increased the frequency of `leaky pollen`. The increased frequency of the leaky pollen suggests that a damage in the pollen envelope would be induced at the range-end. (orig.)}
place = {Germany}
year = {1997}
month = {Sep}
}