You need JavaScript to view this

Triangular tube proportional wire chamber system

Abstract

We report on the characteristics of the proportional tube chamber system which has been constructed for muon identification in the PEP-4 experiment at SLAC. The mechanical and electrical properties of the extruded aluminum triangular tubes allow these detectors to be used as crude drift chambers.
Authors:
Badtke, D H; Bakken, J A; Barnett, B A; Blumenfeld, B J; Chien, C Y; Madansky, L; Matthews, J A.J.; Pevsner, A; Spangler, W J; [1]  Lee, K L [2] 
  1. Johns Hopkins Univ., Baltimore, MD (USA)
  2. California Univ., Berkeley (USA). Lawrence Berkeley Lab.
Publication Date:
Oct 15, 1981
Product Type:
Journal Article
Reference Number:
AIX-13-659949; ERA-07-028429; EDB-82-066975
Resource Relation:
Journal Name: Nucl. Instrum. Methods Phys. Res.; (Netherlands); Journal Volume: 188:3
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; DRIFT CHAMBERS; MULTIWIRE PROPORTIONAL CHAMBERS; MUON DETECTION; EFFICIENCY; ELECTRON DRIFT; PARTICLE IDENTIFICATION; POSITION SENSITIVE DETECTORS; PREAMPLIFIERS; READOUT SYSTEMS; AMPLIFIERS; CHARGED PARTICLE DETECTION; DETECTION; ELECTRONIC EQUIPMENT; EQUIPMENT; MEASURING INSTRUMENTS; PROPORTIONAL COUNTERS; RADIATION DETECTION; RADIATION DETECTORS; 440104* - Radiation Instrumentation- High Energy Physics Instrumentation
OSTI ID:
5769332
Country of Origin:
Netherlands
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: NIMRD
Submitting Site:
INIS
Size:
Pages: 497-506
Announcement Date:
Mar 01, 1982

Citation Formats

Badtke, D H, Bakken, J A, Barnett, B A, Blumenfeld, B J, Chien, C Y, Madansky, L, Matthews, J A.J., Pevsner, A, Spangler, W J, and Lee, K L. Triangular tube proportional wire chamber system. Netherlands: N. p., 1981. Web. doi:10.1016/0029-554X(81)90260-3.
Badtke, D H, Bakken, J A, Barnett, B A, Blumenfeld, B J, Chien, C Y, Madansky, L, Matthews, J A.J., Pevsner, A, Spangler, W J, & Lee, K L. Triangular tube proportional wire chamber system. Netherlands. https://doi.org/10.1016/0029-554X(81)90260-3
Badtke, D H, Bakken, J A, Barnett, B A, Blumenfeld, B J, Chien, C Y, Madansky, L, Matthews, J A.J., Pevsner, A, Spangler, W J, and Lee, K L. 1981. "Triangular tube proportional wire chamber system." Netherlands. https://doi.org/10.1016/0029-554X(81)90260-3.
@misc{etde_5769332,
title = {Triangular tube proportional wire chamber system}
author = {Badtke, D H, Bakken, J A, Barnett, B A, Blumenfeld, B J, Chien, C Y, Madansky, L, Matthews, J A.J., Pevsner, A, Spangler, W J, and Lee, K L}
abstractNote = {We report on the characteristics of the proportional tube chamber system which has been constructed for muon identification in the PEP-4 experiment at SLAC. The mechanical and electrical properties of the extruded aluminum triangular tubes allow these detectors to be used as crude drift chambers.}
doi = {10.1016/0029-554X(81)90260-3}
journal = []
volume = {188:3}
journal type = {AC}
place = {Netherlands}
year = {1981}
month = {Oct}
}