You need JavaScript to view this

The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis

Abstract

Measurement of human motion is important in the application of ergonomics. We developed a system which can measure body movement, especially= hand movement using advanced direct video measurement technology. This system has as dynamic accuracy with 1% error and the sampling rate to 6 - 10 Hz, and can analyse the trajectory and speed of the marker. The use of passive marker obviates the need for a marker telemetry system and minimize motion disruption. 18 refs., 4 tabs., 6 figs. (author)
Authors:
Park, Kyung Soo; Pan, Young Hwan; Lee, Ahn Jae; Lee, Kyung Tae; Lim, Chi Hwan; Chang, Pil Sik; Lee, Seok Woo; Han, Sung Wook; Park, Chul Wook [1] 
  1. Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)
Publication Date:
Jul 01, 1996
Product Type:
Technical Report
Report Number:
KAERI-CM-017/95
Reference Number:
SCA: 440400; PA: KR-97:000783; EDB-98:025718; NTS-98:004012; SN: 98001897059
Resource Relation:
Other Information: PBD: Jul 1996
Subject:
44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; HUMAN FACTORS; THREE-DIMENSIONAL CALCULATIONS; MOTION; TELEMETRY; ON-LINE MEASUREMENT SYSTEMS
OSTI ID:
575327
Research Organizations:
Korea Advanced Energy Research Inst., Daeduk-Danji (Korea, Republic of). Korea Nuclear Safety Center
Country of Origin:
Korea, Republic of
Language:
Korean
Other Identifying Numbers:
Other: ON: DE98724956; TRN: KR9700783
Availability:
OSTI as DE98724956
Submitting Site:
KR
Size:
80 p.
Announcement Date:
Mar 25, 1998

Citation Formats

Park, Kyung Soo, Pan, Young Hwan, Lee, Ahn Jae, Lee, Kyung Tae, Lim, Chi Hwan, Chang, Pil Sik, Lee, Seok Woo, Han, Sung Wook, and Park, Chul Wook. The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis. Korea, Republic of: N. p., 1996. Web.
Park, Kyung Soo, Pan, Young Hwan, Lee, Ahn Jae, Lee, Kyung Tae, Lim, Chi Hwan, Chang, Pil Sik, Lee, Seok Woo, Han, Sung Wook, & Park, Chul Wook. The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis. Korea, Republic of.
Park, Kyung Soo, Pan, Young Hwan, Lee, Ahn Jae, Lee, Kyung Tae, Lim, Chi Hwan, Chang, Pil Sik, Lee, Seok Woo, Han, Sung Wook, and Park, Chul Wook. 1996. "The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis." Korea, Republic of.
@misc{etde_575327,
title = {The development of human factors experimental evaluation technology - 3-dimensional measurement system for motion analysis}
author = {Park, Kyung Soo, Pan, Young Hwan, Lee, Ahn Jae, Lee, Kyung Tae, Lim, Chi Hwan, Chang, Pil Sik, Lee, Seok Woo, Han, Sung Wook, and Park, Chul Wook}
abstractNote = {Measurement of human motion is important in the application of ergonomics. We developed a system which can measure body movement, especially= hand movement using advanced direct video measurement technology. This system has as dynamic accuracy with 1% error and the sampling rate to 6 - 10 Hz, and can analyse the trajectory and speed of the marker. The use of passive marker obviates the need for a marker telemetry system and minimize motion disruption. 18 refs., 4 tabs., 6 figs. (author)}
place = {Korea, Republic of}
year = {1996}
month = {Jul}
}