You need JavaScript to view this

Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen

Abstract

The geothermal heat exchanger transfers heat geothermal heat through the metal wall of the outer pipe to the circulating water. The clean water heats up on its way down and is then pumped up again through the insulated inner riser pipe. The heated water is used for district heating. Drilling started on 26 March 1994, and the system was commissioned on 10 November 1994. Today, it supplies heat and warm water to about 1100 apartments. During its first year of operation the Prenzlau geothermal heat exchanger, which is 2800 m deep, covered more than 20 % of the heat demand of the Prenzlau-West district heating grid. The seasonal performance factor in continuous operation of the 500 kW system is between 8 and 12 % of the weather-dependent peak load, with hourly peaks of more than 700 kW. (orig./AKF) [Deutsch] Die Erdwaermetiefensonde nutzt die Waermeuebertragung vom warmen Erdreich durch die Metallwand des Aussenrohrs zum darin zirkulierenden Wasser. Das eingeleitete saubere Wasser erwaermt sich an der aeusseren Rohrwandung auf dem Weg nach unten und wird dann im inneren waermeisolierten Steigrohr an die Oberflaeche befoerdert. Das erwaermte Waser wird in Prenzlau ueber eine Waermepumpe zu Fernwaermezwecken benutzt. Am 26.3.1994 begannen die Bohrarbeiten, und  More>>
Authors:
Schneider, D; [1]  Brossmann, E; Wetzel, H [2] 
  1. KEMA-IEV GmbH, Dresden (Germany)
  2. VEAG Berlin (Germany)
Publication Date:
Dec 01, 1997
Product Type:
Conference
Report Number:
ETDE-DE-597; CONF-9609413-
Reference Number:
SCA: 150303; PA: DE-97:0GH974; EDB-98:027986; SN: 97001883261
Resource Relation:
Conference: 4. meeting on geothermics - 7. experts meeting of Schweizerische Vereinigung fuer Geothermie (SVG): Geothermics - energy for the future, 4. Geothermische Fachtagung - 7. Fachtagung der Schweizerischen Vereinigung fuer Geothermie (SVG): Geothermie - Energie der Zukunft, Konstanz (Germany), 18-20 Sep 1996; Other Information: PBD: 1997; Related Information: Is Part Of Geothermics - energy for the future. Proceedings; PB: 499 p.; Geothermie - Energie der Zukunft. Tagungsband
Subject:
15 GEOTHERMAL ENERGY; GEOTHERMAL HEATING SYSTEMS; HEAT PUMPS; GEOTHERMAL WELLS; PROBES; PIPES; DESIGN; OPERATION; CROSS SECTIONS; DIMENSIONS; DATA
OSTI ID:
573617
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE98714933; ISBN 3-932570-09-X; TRN: DE97GH974
Availability:
OSTI as DE98714933
Submitting Site:
DE
Size:
pp. 335-340
Announcement Date:
Apr 10, 1998

Citation Formats

Schneider, D, Brossmann, E, and Wetzel, H. Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen. Germany: N. p., 1997. Web.
Schneider, D, Brossmann, E, & Wetzel, H. Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen. Germany.
Schneider, D, Brossmann, E, and Wetzel, H. 1997. "Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen." Germany.
@misc{etde_573617,
title = {Prenzlau geothermal heat exchanger - technical concept and performance; Erdwaermetiefensonde Prenzlau - technisches Konzept und Betriebserfahrungen}
author = {Schneider, D, Brossmann, E, and Wetzel, H}
abstractNote = {The geothermal heat exchanger transfers heat geothermal heat through the metal wall of the outer pipe to the circulating water. The clean water heats up on its way down and is then pumped up again through the insulated inner riser pipe. The heated water is used for district heating. Drilling started on 26 March 1994, and the system was commissioned on 10 November 1994. Today, it supplies heat and warm water to about 1100 apartments. During its first year of operation the Prenzlau geothermal heat exchanger, which is 2800 m deep, covered more than 20 % of the heat demand of the Prenzlau-West district heating grid. The seasonal performance factor in continuous operation of the 500 kW system is between 8 and 12 % of the weather-dependent peak load, with hourly peaks of more than 700 kW. (orig./AKF) [Deutsch] Die Erdwaermetiefensonde nutzt die Waermeuebertragung vom warmen Erdreich durch die Metallwand des Aussenrohrs zum darin zirkulierenden Wasser. Das eingeleitete saubere Wasser erwaermt sich an der aeusseren Rohrwandung auf dem Weg nach unten und wird dann im inneren waermeisolierten Steigrohr an die Oberflaeche befoerdert. Das erwaermte Waser wird in Prenzlau ueber eine Waermepumpe zu Fernwaermezwecken benutzt. Am 26.3.1994 begannen die Bohrarbeiten, und am 10.11.1994 ging die gesamte Anlage in Betrieb, die heute ca. 1100 Wohnungen mit Waerme und Warmwasser versorgt. Die Erdwaermetiefensonde Prenzlau mit einer Tiefe von 2800 m deckte in den ersten beiden Betriebsjahren ueber 20 % des Waermebedarfs des Fernwaermenetzes Prenzlau-West. Die Jahresdauerleistung der Erdwaermetiefensonde mit 500 kW liegt bei 8-12 % der witterungsbedingten Jahreshoechstlast. Die Sonde gestattet Spitzenleistungen im Stundenbereich von mehr als 700 kW. (orig./AKF)}
place = {Germany}
year = {1997}
month = {Dec}
}