You need JavaScript to view this

Geomicrobiological analysis of highly mineralized geothermal waters as a contribution to the optimum use of geothermal energy; Geomikrobiologische Forschungsarbeiten an hochmineralisierten Tiefenwaessern als Beitrag zur optimalen Nutzung geothermischer Energie

Abstract

In the context of a BMBF-funded project for Mecklenburg-Vorpommern, `Geomicrobiological analysis of geothermal waters used for energy generation`, the authors continued the series of microbiological analyses of the thermal water of the geothermal heating station at Neustadt-Glewe beyond full commissioning of the plant in April 1995. Their activities also included performance of model experiments for examination of the conditions causing massive development of microorganisms in the aquifer or in the thermal water loops of the heating station. The experimental results show that compliance with the findings and recommended operational measures will guarantee long-term operating stability of the heating station. However, in-service microbiological monitoring routines are required in order to early detect and prevent unwanted processes in the thermal water system. (orig.) [Deutsch] Im Rahmen des vom BMBF gefoerderten Projektes `Geomikrobiologische Untersuchungen an geothermisch genutzten Tiefenwaessern Nordostdeutschlands` (Mecklenburg-Vorpommern) haben wir uns auch nach voller Inbetriebnahme des Erdwaerme-Heizwerkes Neustadt-Glewe (April 1995) auf die mikrobiologische Analyse des Thermalwassers konzentriert. Darueber hinaus wurde in Modellversuchen geprueft, unter welchen Bedingungen eine Massenentwicklung von Mikroorganismen im Aquifer bzw. Thermalwasserkreislauf moeglich ist. Die Versuche haben gezeigt, dass unter Beachtung der erzielten Befunde bei sachgemaesser Betriebsfuehrung die Langzeitstabilitaet der Anlage gewaehrleistet ist. Jedoch sind mikrobiologische Betriebskontrollen unerlaesslich, um  More>>
Authors:
Koehler, M; Voelsgen, F; Hofmann, K; Bochning, S; [1]  Keller, T [2] 
  1. URST Umwelt- und Rohstoff-Technologie, Greifswald (Germany)
  2. Geothermie Neubrandenburg GmbH (Germany)
Publication Date:
Dec 01, 1997
Product Type:
Conference
Report Number:
ETDE-DE-597; CONF-9609413-
Reference Number:
SCA: 150302; 550700; PA: DE-97:0GH996; EDB-98:027985; SN: 97001883239
Resource Relation:
Conference: 4. meeting on geothermics - 7. experts meeting of Schweizerische Vereinigung fuer Geothermie (SVG): Geothermics - energy for the future, 4. Geothermische Fachtagung - 7. Fachtagung der Schweizerischen Vereinigung fuer Geothermie (SVG): Geothermie - Energie der Zukunft, Konstanz (Germany), 18-20 Sep 1996; Other Information: PBD: 1997; Related Information: Is Part Of Geothermics - energy for the future. Proceedings; PB: 499 p.; Geothermie - Energie der Zukunft. Tagungsband
Subject:
15 GEOTHERMAL ENERGY; 55 BIOLOGY AND MEDICINE, BASIC STUDIES; MICROORGANISMS; MINERAL SPRINGS; CHEMICAL ANALYSIS; OPTIMIZATION; GEOTHERMAL ENERGY; TECHNOLOGY UTILIZATION; WATER POLLUTION MONITORS
OSTI ID:
573555
Country of Origin:
Germany
Language:
German
Other Identifying Numbers:
Other: ON: DE98714933; ISBN 3-932570-09-X; TRN: DE97GH996
Availability:
OSTI as DE98714933
Submitting Site:
DE
Size:
pp. 136-141
Announcement Date:

Citation Formats

Koehler, M, Voelsgen, F, Hofmann, K, Bochning, S, and Keller, T. Geomicrobiological analysis of highly mineralized geothermal waters as a contribution to the optimum use of geothermal energy; Geomikrobiologische Forschungsarbeiten an hochmineralisierten Tiefenwaessern als Beitrag zur optimalen Nutzung geothermischer Energie. Germany: N. p., 1997. Web.
Koehler, M, Voelsgen, F, Hofmann, K, Bochning, S, & Keller, T. Geomicrobiological analysis of highly mineralized geothermal waters as a contribution to the optimum use of geothermal energy; Geomikrobiologische Forschungsarbeiten an hochmineralisierten Tiefenwaessern als Beitrag zur optimalen Nutzung geothermischer Energie. Germany.
Koehler, M, Voelsgen, F, Hofmann, K, Bochning, S, and Keller, T. 1997. "Geomicrobiological analysis of highly mineralized geothermal waters as a contribution to the optimum use of geothermal energy; Geomikrobiologische Forschungsarbeiten an hochmineralisierten Tiefenwaessern als Beitrag zur optimalen Nutzung geothermischer Energie." Germany.
@misc{etde_573555,
title = {Geomicrobiological analysis of highly mineralized geothermal waters as a contribution to the optimum use of geothermal energy; Geomikrobiologische Forschungsarbeiten an hochmineralisierten Tiefenwaessern als Beitrag zur optimalen Nutzung geothermischer Energie}
author = {Koehler, M, Voelsgen, F, Hofmann, K, Bochning, S, and Keller, T}
abstractNote = {In the context of a BMBF-funded project for Mecklenburg-Vorpommern, `Geomicrobiological analysis of geothermal waters used for energy generation`, the authors continued the series of microbiological analyses of the thermal water of the geothermal heating station at Neustadt-Glewe beyond full commissioning of the plant in April 1995. Their activities also included performance of model experiments for examination of the conditions causing massive development of microorganisms in the aquifer or in the thermal water loops of the heating station. The experimental results show that compliance with the findings and recommended operational measures will guarantee long-term operating stability of the heating station. However, in-service microbiological monitoring routines are required in order to early detect and prevent unwanted processes in the thermal water system. (orig.) [Deutsch] Im Rahmen des vom BMBF gefoerderten Projektes `Geomikrobiologische Untersuchungen an geothermisch genutzten Tiefenwaessern Nordostdeutschlands` (Mecklenburg-Vorpommern) haben wir uns auch nach voller Inbetriebnahme des Erdwaerme-Heizwerkes Neustadt-Glewe (April 1995) auf die mikrobiologische Analyse des Thermalwassers konzentriert. Darueber hinaus wurde in Modellversuchen geprueft, unter welchen Bedingungen eine Massenentwicklung von Mikroorganismen im Aquifer bzw. Thermalwasserkreislauf moeglich ist. Die Versuche haben gezeigt, dass unter Beachtung der erzielten Befunde bei sachgemaesser Betriebsfuehrung die Langzeitstabilitaet der Anlage gewaehrleistet ist. Jedoch sind mikrobiologische Betriebskontrollen unerlaesslich, um unerwuenschte Prozesse im Thermalwassersystem rechtzeitig erkenn en und verhindern zu koennen. (orig.)}
place = {Germany}
year = {1997}
month = {Dec}
}