You need JavaScript to view this

Pulse shape simulation for drift chambers with long drift paths

Abstract

A detailed Monte Carlo program for the simulation of drift chamber pulse shapes is described. It has been applied to the case of a jet chamber with drift paths up to 24 cm. Results on pulse shapes and corresponding spatial and double hit resolution are discussed and compared to recent measurements of the OPAL central detector jet chamber full size prototype and to measurements of a small 20-wire prototype, which was designed to study the pulse shapes generated by tracks in a magnetic field. Simulated pulse shapes and spatial resolutions agree well with the experimental data. Clustering, saturation and wire crosstalk are shown to be necessary ingredients in the simulation. A deterioration in resolution due to the influence of crosstalk signals is correctly reproduced, as well as the cancellation of this effect by a hardwired first and second neighbour crosstalk compensation. The simulation correctly describes the asymmetry in spatial resolution observed for tracks with positive or negative inclination against the wire plane when a magnetic field is present. The effect of saturation on double hit resolution is found to be small. The magnetic field is predicted to improve the double hit resolution.
Authors:
Publication Date:
Sep 15, 1987
Product Type:
Journal Article
Reference Number:
AIX-19-014111; EDB-88-030255
Resource Relation:
Journal Name: Nucl. Instrum. Methods Phys. Res., Sect. A.; (Netherlands); Journal Volume: 259:3
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; DRIFT CHAMBERS; PULSES; ACCURACY; ARGON; ASYMMETRY; COMPUTER CODES; COMPUTERIZED SIMULATION; EFFICIENCY; ELECTRON DRIFT; GEOMETRY; MAGNETIC FIELDS; MONTE CARLO METHOD; PARTICLE TRACKS; SPATIAL RESOLUTION; TIMING PROPERTIES; ELEMENTS; FLUIDS; GASES; MATHEMATICS; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBERS; NONMETALS; PROPORTIONAL COUNTERS; RADIATION DETECTORS; RARE GASES; RESOLUTION; SIMULATION; 440104* - Radiation Instrumentation- High Energy Physics Instrumentation
OSTI ID:
5672299
Research Organizations:
Freiburg Univ., Germany, F.R.. Fakultaet fuer Physik
Country of Origin:
Netherlands
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: NIMAE
Submitting Site:
INIS
Size:
Pages: 447-458
Announcement Date:
Feb 01, 1988

Citation Formats

Mayer, H J. Pulse shape simulation for drift chambers with long drift paths. Netherlands: N. p., 1987. Web. doi:10.1016/0168-9002(87)90826-6.
Mayer, H J. Pulse shape simulation for drift chambers with long drift paths. Netherlands. https://doi.org/10.1016/0168-9002(87)90826-6
Mayer, H J. 1987. "Pulse shape simulation for drift chambers with long drift paths." Netherlands. https://doi.org/10.1016/0168-9002(87)90826-6.
@misc{etde_5672299,
title = {Pulse shape simulation for drift chambers with long drift paths}
author = {Mayer, H J}
abstractNote = {A detailed Monte Carlo program for the simulation of drift chamber pulse shapes is described. It has been applied to the case of a jet chamber with drift paths up to 24 cm. Results on pulse shapes and corresponding spatial and double hit resolution are discussed and compared to recent measurements of the OPAL central detector jet chamber full size prototype and to measurements of a small 20-wire prototype, which was designed to study the pulse shapes generated by tracks in a magnetic field. Simulated pulse shapes and spatial resolutions agree well with the experimental data. Clustering, saturation and wire crosstalk are shown to be necessary ingredients in the simulation. A deterioration in resolution due to the influence of crosstalk signals is correctly reproduced, as well as the cancellation of this effect by a hardwired first and second neighbour crosstalk compensation. The simulation correctly describes the asymmetry in spatial resolution observed for tracks with positive or negative inclination against the wire plane when a magnetic field is present. The effect of saturation on double hit resolution is found to be small. The magnetic field is predicted to improve the double hit resolution.}
doi = {10.1016/0168-9002(87)90826-6}
journal = []
volume = {259:3}
journal type = {AC}
place = {Netherlands}
year = {1987}
month = {Sep}
}