Abstract

The geometry of the vertex chamber for the OPAL detector at LEP is reviewed and expressions for the coordinates of the hits are given in terms of the measured drift distance and z-coordinate. The tracks are fitted by a procedure based on the Lagrange multipliers method. The increase in the accuracy of the fit due to the use of the stereo wires is discussed.
Publication Date:
Oct 01, 1987
Product Type:
Journal Article
Reference Number:
NLN-88-000652; EDB-88-041811
Resource Relation:
Journal Name: Nucl. Instrum. Methods Phys. Res.; (Netherlands); Journal Volume: 260:1
Subject:
46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; GAS TRACK DETECTORS; DATA PROCESSING; ACCURACY; COORDINATES; DRIFT CHAMBERS; MONTE CARLO METHOD; PARTICLE TRACKS; WIRES; MEASURING INSTRUMENTS; MULTIWIRE PROPORTIONAL CHAMBERS; PROCESSING; PROPORTIONAL COUNTERS; RADIATION DETECTORS; 440104* - Radiation Instrumentation- High Energy Physics Instrumentation
OSTI ID:
5656055
Research Organizations:
Carleton Univ., Ottawa, Ontario, Canada. Dept. of Physics
Country of Origin:
Netherlands
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: NIMRD
Submitting Site:
NLN
Size:
Pages: 132-141
Announcement Date:
Feb 01, 1988

Citation Formats

Shally, R, Hemingway, R J, and McPherson, A C. Track fitting in the opal vertex detector with stereo wires. Netherlands: N. p., 1987. Web. doi:10.1016/0168-9002(87)90394-9.
Shally, R, Hemingway, R J, & McPherson, A C. Track fitting in the opal vertex detector with stereo wires. Netherlands. https://doi.org/10.1016/0168-9002(87)90394-9
Shally, R, Hemingway, R J, and McPherson, A C. 1987. "Track fitting in the opal vertex detector with stereo wires." Netherlands. https://doi.org/10.1016/0168-9002(87)90394-9.
@misc{etde_5656055,
title = {Track fitting in the opal vertex detector with stereo wires}
author = {Shally, R, Hemingway, R J, and McPherson, A C}
abstractNote = {The geometry of the vertex chamber for the OPAL detector at LEP is reviewed and expressions for the coordinates of the hits are given in terms of the measured drift distance and z-coordinate. The tracks are fitted by a procedure based on the Lagrange multipliers method. The increase in the accuracy of the fit due to the use of the stereo wires is discussed.}
doi = {10.1016/0168-9002(87)90394-9}
journal = []
volume = {260:1}
journal type = {AC}
place = {Netherlands}
year = {1987}
month = {Oct}
}