Static compensators using thyristor control with saturated or low-reactance linear reactors

Journal Article:

Abstract

Alternative key components of variable static equipment for reactive power compensation and voltage control in a.c. transmission systems are saturated reactors (SR) and thyristor-controlled reactors (TCR). This paper reports some recent developments aimed at improving the performance and economy of both types of scheme. Advantages of using low-percentage reactance values in a TCR scheme are considered, and methods of dealing with the increased harmonic distortions and of employing transformer leakage reactance. The paper discusses the possibility of combining the advantages of 'external' thyristor control with the 'inherent' action of the harmonic-compensated SR, and the performance of a practical TCSR is presented.
Publication Date:
Jan 01, 1982
Product Type:
Journal Article
Reference Number:
EDB-83-184731
Resource Relation:
Journal Name: J. Sci. Technol.; (United Kingdom); Journal Volume: 48:3
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; POWER TRANSMISSION; SHUNT REACTORS; THYRISTORS; CONTROL SYSTEMS; COST; ELECTRICAL ENGINEERING; ELECTROSTATIC CHARGE ELIMINATORS; PERFORMANCE; ELECTRICAL EQUIPMENT; ENGINEERING; EQUIPMENT; SEMICONDUCTOR DEVICES; 200301* - Power Transmission & Distribution- AC Systems, EHV & UHV- (-1989)
OSTI ID:
5569286
Research Organizations:
GEC High Voltage Switchgear Ltd., England
Country of Origin:
United Kingdom
Language:
English
Other Identifying Numbers:
Journal ID: CODEN: JSTGA
Submitting Site:
HEDB
Size:
Pages: 163-169
Announcement Date:

Journal Article:

Citation Formats

Thanawala, H L, Kelham, W O, and Crawshaw, A W. Static compensators using thyristor control with saturated or low-reactance linear reactors. United Kingdom: N. p., 1982. Web.
Thanawala, H L, Kelham, W O, & Crawshaw, A W. Static compensators using thyristor control with saturated or low-reactance linear reactors. United Kingdom.
Thanawala, H L, Kelham, W O, and Crawshaw, A W. 1982. "Static compensators using thyristor control with saturated or low-reactance linear reactors." United Kingdom.
@misc{etde_5569286,
title = {Static compensators using thyristor control with saturated or low-reactance linear reactors}
author = {Thanawala, H L, Kelham, W O, and Crawshaw, A W}
abstractNote = {Alternative key components of variable static equipment for reactive power compensation and voltage control in a.c. transmission systems are saturated reactors (SR) and thyristor-controlled reactors (TCR). This paper reports some recent developments aimed at improving the performance and economy of both types of scheme. Advantages of using low-percentage reactance values in a TCR scheme are considered, and methods of dealing with the increased harmonic distortions and of employing transformer leakage reactance. The paper discusses the possibility of combining the advantages of 'external' thyristor control with the 'inherent' action of the harmonic-compensated SR, and the performance of a practical TCSR is presented.}
journal = {J. Sci. Technol.; (United Kingdom)}
volume = {48:3}
journal type = {AC}
place = {United Kingdom}
year = {1982}
month = {Jan}
}