The calibration method for personal dosimetry system in photon and neutron radiation fields

Abstract

The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).
Authors:
Trousil, J; Plichta, J; [1]  Nikodemova, D [2] 
  1. CSOD, Prague (Czech Republic)
  2. SOD, Bratislava (Slovakia)
Publication Date:
Dec 31, 1995
Product Type:
Conference
Report Number:
INIS-SK-97-001; CONF-9511264-
Reference Number:
SCA: 560101; 440102; PA: AIX-28:074033; EDB-98:003595; SN: 97001879422
Resource Relation:
Conference: 19. radiation hygiene days (RHD) Jasna, Jasna Pod Chopkom (Slovakia), 20-23 Nov 1995; Other Information: PBD: 1995; Related Information: Is Part Of 19th Radiation Hygiene Days. Conference Proceedings; PB: 208 p.
Subject:
56 BIOLOGY AND MEDICINE, APPLIED STUDIES; 44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; PERSONNEL DOSIMETRY; CALIBRATION; NEUTRON DOSIMETRY; ELECTRON DOSIMETRY; GAMMA DOSIMETRY; IAEA; ICRU; IONIZING RADIATIONS; PERSONNEL MONITORING; RADIATION DOSES; RADIATION MONITORING
OSTI ID:
551057
Research Organizations:
Slovak Medical Association, Bratislava (Slovakia). Society of Nuclear Medicine and Radiation Hygiene; Institute of Preventive and Clinical Medicine, Bratislava (Slovakia); State Specialized Health Inst., Banska Bystrica (Slovakia)
Country of Origin:
Slovakia
Language:
English
Other Identifying Numbers:
Other: ON: DE98604320; TRN: SK97K0196074033
Availability:
INIS; OSTI as DE98604320
Submitting Site:
INIS
Size:
pp. 51-52
Announcement Date:

Citation Formats

Trousil, J, Plichta, J, and Nikodemova, D. The calibration method for personal dosimetry system in photon and neutron radiation fields. Slovakia: N. p., 1995. Web.
Trousil, J, Plichta, J, & Nikodemova, D. The calibration method for personal dosimetry system in photon and neutron radiation fields. Slovakia.
Trousil, J, Plichta, J, and Nikodemova, D. 1995. "The calibration method for personal dosimetry system in photon and neutron radiation fields." Slovakia.
@misc{etde_551057,
title = {The calibration method for personal dosimetry system in photon and neutron radiation fields}
author = {Trousil, J, Plichta, J, and Nikodemova, D}
abstractNote = {The type testing of dosimetry system was performed with standard photon radiation fields within the energy range 15 keV to 1.25 MeV and electron radiation fields within the range 0.2 MeV to 3 MeV. For type testing of neutron dosimeters {sup 252}Cf and {sup 241}Am-Be radionuclide neutron sources was used, as well as a 14 MeV neutron generator. The neutron sources moderated by various moderating and absorbing materials was also used. The routine calibration of individual photon dosemeters was carried out using a {sup 137}Cs calibration source in the air kerma quality in the dose range 0.2 mGy to 6 Gy. The type testing of neutron dosemeters was performed in collaboration with Nueherberg laboratory on neutron generator with neutron energies -.57; 1.0;; 5.3 and 15.1 MeV. The fading and angular dependence testing was also included in the tests of both dosemeter systems. (J.K.).}
place = {Slovakia}
year = {1995}
month = {Dec}
}