To the use of bubble detectors in personal neutron dosimetry

Abstract

In this paper the commercially available bubble neutron detectors (bubble damage neutron detectors (BDNDs*) from Bubble Technology Industries, Chalk River; and superheated drop detectors (SDDs*) from APFEL Industries, New Haven) for lowest limit of detection of an individual neutron dosimeter were tested. They were tested with the different neutron sources. BDNDs* tested had the sensitivity about 1 bubble per 1 Sv of H*(10) of AmBe neutrons, they were evaluated by eye counting (20 to 30 bubbles per detector). Two types of reusable BDNDs* were tested: BD-100R without and with temperature compensation, both with neutron energy threshold about 100 keV. SDDs* tested had the sensitivity about 3 bubbles per 1 {mu}Sv of H*10 from AmBe neutrons, they were evaluated using APFEL Survey Meter Model 202. SDDs* with three different energy thresholds have been used: 0.1, 1 and 6 MeV. For energetical dependence of BDNDs* the general conclusions were formulated in the following way: (1) With the exception of thermal neutron source SIGMA (50% of H*(10) from thermal neutrons) and high energy reference fields there is a reasonable agreement of data measured with BDNDs* and expected values; (2) the new lots to have a little different energetic dependence. The relative responses for  More>>
Authors:
Spurny, F; Vlcek, B [1] 
  1. Academy of the Sciences of Czech Republic, Prague (Czech Republic). Nuclear Physics Institute, Department of Radiation Dosimetry
Publication Date:
Dec 31, 1995
Product Type:
Miscellaneous
Report Number:
INIS-SK-97-001; CONF-9511264-
Reference Number:
SCA: 560101; 440102; PA: AIX-28:074031; EDB-98:003594; SN: 97001879420
Resource Relation:
Conference: 19. radiation hygiene days (RHD) Jasna, Jasna Pod Chopkom (Slovakia), 20-23 Nov 1995; Other Information: PBD: 1995; Related Information: Is Part Of 19th Radiation Hygiene Days. Conference Proceedings; PB: 208 p.
Subject:
56 BIOLOGY AND MEDICINE, APPLIED STUDIES; 44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; PERSONNEL DOSIMETRY; NEUTRON DETECTORS; EXPERIMENTAL DATA; HEALTH HAZARDS; IONIZING RADIATIONS; NEUTRON DETECTION; PERSONNEL MONITORING; RADIATION DOSES; RADIATION MONITORING; RADIATION PROTECTION
OSTI ID:
551056
Research Organizations:
Slovak Medical Association, Bratislava (Slovakia). Society of Nuclear Medicine and Radiation Hygiene; Institute of Preventive and Clinical Medicine, Bratislava (Slovakia); State Specialized Health Inst., Banska Bystrica (Slovakia)
Country of Origin:
Slovakia
Language:
English
Other Identifying Numbers:
Other: ON: DE98604320; CNN: EC Project FI3P-CT93-0072; TRN: SK97K0191074031
Availability:
INIS; OSTI as DE98604320
Submitting Site:
INIS
Size:
pp. 43-45
Announcement Date:
Dec 30, 1997

Citation Formats

Spurny, F, and Vlcek, B. To the use of bubble detectors in personal neutron dosimetry. Slovakia: N. p., 1995. Web.
Spurny, F, & Vlcek, B. To the use of bubble detectors in personal neutron dosimetry. Slovakia.
Spurny, F, and Vlcek, B. 1995. "To the use of bubble detectors in personal neutron dosimetry." Slovakia.
@misc{etde_551056,
title = {To the use of bubble detectors in personal neutron dosimetry}
author = {Spurny, F, and Vlcek, B}
abstractNote = {In this paper the commercially available bubble neutron detectors (bubble damage neutron detectors (BDNDs*) from Bubble Technology Industries, Chalk River; and superheated drop detectors (SDDs*) from APFEL Industries, New Haven) for lowest limit of detection of an individual neutron dosimeter were tested. They were tested with the different neutron sources. BDNDs* tested had the sensitivity about 1 bubble per 1 Sv of H*(10) of AmBe neutrons, they were evaluated by eye counting (20 to 30 bubbles per detector). Two types of reusable BDNDs* were tested: BD-100R without and with temperature compensation, both with neutron energy threshold about 100 keV. SDDs* tested had the sensitivity about 3 bubbles per 1 {mu}Sv of H*10 from AmBe neutrons, they were evaluated using APFEL Survey Meter Model 202. SDDs* with three different energy thresholds have been used: 0.1, 1 and 6 MeV. For energetical dependence of BDNDs* the general conclusions were formulated in the following way: (1) With the exception of thermal neutron source SIGMA (50% of H*(10) from thermal neutrons) and high energy reference fields there is a reasonable agreement of data measured with BDNDs* and expected values; (2) the new lots to have a little different energetic dependence. The relative responses for `soft` fields are for them systematically higher than for previous samples. The response to energies between 0.01 and 1 MeV is for these lots relatively higher. (3) The underestimation of high energy neutrons is typical for any LET-threshold type detectors.It should be kept in mind when BDNDs* are used as dosemeters in high energy neutron environment. For energetical dependence of SDDs* was concluded: (1) The energetical dependence of SDD 100 is comparable with the dependencies of BD-100R and PND, the underestimation of high energy neutrons included; (2) The use of SDD with different energy thresholds can provide interesting spectrometric information; (Abstract Truncated)}
place = {Slovakia}
year = {1995}
month = {Dec}
}