Abstract
An instrumental neutron activation analysis for the simultaneous determination of chlorine, bromine, sodium, manganese, cobalt, copper, chromium, zinc, nickel, antimony and iron in waste water is described. They were determined in waste water samples under normal conditions by non-destructive neutron activation simultaneously using a suitable monostandard method. Standardized water samples were used and irradiated in polyethylene ampoules at a neutron flux of 10{sup 13} cm{sup -2} s{sup -1} for periods of 1 minute, 1 and 10 hours. A Ge hyperpure detector was used for your activity determination, with count times of 60, 180, 300 and 600 seconds. The obtained results show than the method can be utilized for the determination of this elements without realize anything previous treatment of the samples. (Author).
Citation Formats
Hernandez H, V.
Neutron Activation analysis of waste water; Analisis de aguas residuales mediante activacion neutronica.
Mexico: N. p.,
1997.
Web.
Hernandez H, V.
Neutron Activation analysis of waste water; Analisis de aguas residuales mediante activacion neutronica.
Mexico.
Hernandez H, V.
1997.
"Neutron Activation analysis of waste water; Analisis de aguas residuales mediante activacion neutronica."
Mexico.
@misc{etde_546400,
title = {Neutron Activation analysis of waste water; Analisis de aguas residuales mediante activacion neutronica}
author = {Hernandez H, V}
abstractNote = {An instrumental neutron activation analysis for the simultaneous determination of chlorine, bromine, sodium, manganese, cobalt, copper, chromium, zinc, nickel, antimony and iron in waste water is described. They were determined in waste water samples under normal conditions by non-destructive neutron activation simultaneously using a suitable monostandard method. Standardized water samples were used and irradiated in polyethylene ampoules at a neutron flux of 10{sup 13} cm{sup -2} s{sup -1} for periods of 1 minute, 1 and 10 hours. A Ge hyperpure detector was used for your activity determination, with count times of 60, 180, 300 and 600 seconds. The obtained results show than the method can be utilized for the determination of this elements without realize anything previous treatment of the samples. (Author).}
place = {Mexico}
year = {1997}
month = {Dec}
}
title = {Neutron Activation analysis of waste water; Analisis de aguas residuales mediante activacion neutronica}
author = {Hernandez H, V}
abstractNote = {An instrumental neutron activation analysis for the simultaneous determination of chlorine, bromine, sodium, manganese, cobalt, copper, chromium, zinc, nickel, antimony and iron in waste water is described. They were determined in waste water samples under normal conditions by non-destructive neutron activation simultaneously using a suitable monostandard method. Standardized water samples were used and irradiated in polyethylene ampoules at a neutron flux of 10{sup 13} cm{sup -2} s{sup -1} for periods of 1 minute, 1 and 10 hours. A Ge hyperpure detector was used for your activity determination, with count times of 60, 180, 300 and 600 seconds. The obtained results show than the method can be utilized for the determination of this elements without realize anything previous treatment of the samples. (Author).}
place = {Mexico}
year = {1997}
month = {Dec}
}