Abstract
Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).
Sawada, S;
Tanabe, Y;
Fujiwara, Y;
Koyama, T;
Tanigawa, N;
Kobayashi, M;
Katsube, Y;
Nakamura, H
[1]
- Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology
Citation Formats
Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H.
Endotracheal expandable metallic stent placement in dogs.
Denmark: N. p.,
1991.
Web.
Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, & Nakamura, H.
Endotracheal expandable metallic stent placement in dogs.
Denmark.
Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H.
1991.
"Endotracheal expandable metallic stent placement in dogs."
Denmark.
@misc{etde_5461381,
title = {Endotracheal expandable metallic stent placement in dogs}
author = {Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H}
abstractNote = {Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).}
journal = []
volume = {32:1}
journal type = {AC}
place = {Denmark}
year = {1991}
month = {Jan}
}
title = {Endotracheal expandable metallic stent placement in dogs}
author = {Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H}
abstractNote = {Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).}
journal = []
volume = {32:1}
journal type = {AC}
place = {Denmark}
year = {1991}
month = {Jan}
}