You need JavaScript to view this

Endotracheal expandable metallic stent placement in dogs

Abstract

Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).
Authors:
Sawada, S; Tanabe, Y; Fujiwara, Y; Koyama, T; Tanigawa, N; Kobayashi, M; Katsube, Y; Nakamura, H [1] 
  1. Tottori Univ. School of Medicine, Yonago (Japan). Dept. of Radiology Research Inst. for Microbial Diseases, Osaka (Japan). Dept. of Radiology
Publication Date:
Jan 01, 1991
Product Type:
Journal Article
Reference Number:
AIX-22-072806; EDB-91-128067
Resource Relation:
Journal Name: Acta Radiologica (1987); (Sweden); Journal Volume: 32:1
Subject:
62 RADIOLOGY AND NUCLEAR MEDICINE; PROSTHESES; POSITIONING; SURGERY; BIOMEDICAL RADIOGRAPHY; TRACHEA; DOGS; METALS; SURGICAL MATERIALS; X-RAY RADIOGRAPHY; ANIMALS; DIAGNOSTIC TECHNIQUES; ELEMENTS; INDUSTRIAL RADIOGRAPHY; MAMMALS; MATERIALS; MEDICAL SUPPLIES; MEDICINE; NUCLEAR MEDICINE; RADIOLOGY; RESPIRATORY SYSTEM; VERTEBRATES; 550602* - Medicine- External Radiation in Diagnostics- (1980-)
OSTI ID:
5461381
Country of Origin:
Denmark
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0284-1851; CODEN: ACRAE
Submitting Site:
DKN
Size:
Pages: 79-80
Announcement Date:
Oct 01, 1991

Citation Formats

Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H. Endotracheal expandable metallic stent placement in dogs. Denmark: N. p., 1991. Web.
Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, & Nakamura, H. Endotracheal expandable metallic stent placement in dogs. Denmark.
Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H. 1991. "Endotracheal expandable metallic stent placement in dogs." Denmark.
@misc{etde_5461381,
title = {Endotracheal expandable metallic stent placement in dogs}
author = {Sawada, S, Tanabe, Y, Fujiwara, Y, Koyama, T, Tanigawa, N, Kobayashi, M, Katsube, Y, and Nakamura, H}
abstractNote = {Various types of Gianturco zig-zag wire stent were implanted into the tracheas of 4 dogs to define the suitable characteristics of the endotracheal wire stent in these animals. These stents were constructed of 0.45, and 0.33 mm stainless steel wire. The diameter of the fully expanded stents was 3 cm and their lengths were 2, 3, and 4 cm. The 2 cm stent constructed of 0.33 mm wire showed minimum pathologic changes of the trachea of the dog compared to the other stents, and at the same time had a complete covering of ciliated columnar epithelium over the stent surface. (orig.).}
journal = []
volume = {32:1}
journal type = {AC}
place = {Denmark}
year = {1991}
month = {Jan}
}