Abstract
An analyzing system with a PDP 11 computer and a digital multiplexer is described. It allows to accept signals from 16 detectors with individual ADCs simultaneously. For measurements of analyzing powers the polarization of the ion beam can be switched to zero with a frequency of 1 kHz. The switching operation additionally controls the handling of the detector pulses. The software contains special programs for the analysis of polarization experiments.
Krause, H H;
Stock, R;
Arnold, W;
Berg, H;
Huttel, E;
Ulbricht, J;
Clausnitzer, G
[1]
- Giessen Univ. (Germany, F.R.). Strahlenzentrum
Citation Formats
Krause, H H, Stock, R, Arnold, W, Berg, H, Huttel, E, Ulbricht, J, and Clausnitzer, G.
Giessen polarization facility. III. Multi-detector analyzing system.
Netherlands: N. p.,
1977.
Web.
doi:10.1016/0029-554X(77)90234-8.
Krause, H H, Stock, R, Arnold, W, Berg, H, Huttel, E, Ulbricht, J, & Clausnitzer, G.
Giessen polarization facility. III. Multi-detector analyzing system.
Netherlands.
https://doi.org/10.1016/0029-554X(77)90234-8
Krause, H H, Stock, R, Arnold, W, Berg, H, Huttel, E, Ulbricht, J, and Clausnitzer, G.
1977.
"Giessen polarization facility. III. Multi-detector analyzing system."
Netherlands.
https://doi.org/10.1016/0029-554X(77)90234-8.
@misc{etde_5424810,
title = {Giessen polarization facility. III. Multi-detector analyzing system}
author = {Krause, H H, Stock, R, Arnold, W, Berg, H, Huttel, E, Ulbricht, J, and Clausnitzer, G}
abstractNote = {An analyzing system with a PDP 11 computer and a digital multiplexer is described. It allows to accept signals from 16 detectors with individual ADCs simultaneously. For measurements of analyzing powers the polarization of the ion beam can be switched to zero with a frequency of 1 kHz. The switching operation additionally controls the handling of the detector pulses. The software contains special programs for the analysis of polarization experiments.}
doi = {10.1016/0029-554X(77)90234-8}
journal = []
volume = {143:3}
journal type = {AC}
place = {Netherlands}
year = {1977}
month = {Jun}
}
title = {Giessen polarization facility. III. Multi-detector analyzing system}
author = {Krause, H H, Stock, R, Arnold, W, Berg, H, Huttel, E, Ulbricht, J, and Clausnitzer, G}
abstractNote = {An analyzing system with a PDP 11 computer and a digital multiplexer is described. It allows to accept signals from 16 detectors with individual ADCs simultaneously. For measurements of analyzing powers the polarization of the ion beam can be switched to zero with a frequency of 1 kHz. The switching operation additionally controls the handling of the detector pulses. The software contains special programs for the analysis of polarization experiments.}
doi = {10.1016/0029-554X(77)90234-8}
journal = []
volume = {143:3}
journal type = {AC}
place = {Netherlands}
year = {1977}
month = {Jun}
}