Pulsed operation of high-pressure-sodium discharge lamps

Journal Article:

Abstract

Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.).
Authors:
Guenther, K; Kloss, H G; Lehmann, T; [1]  Radtke, R; Serick, F [2] 
  1. Zentrum fuer Forschung und Technologie, Berlin (Germany, F.R.)
  2. Zentralinstitut fuer Elektronenphysik, Berlin (Germany, F.R.)
Publication Date:
Jan 01, 1990
Product Type:
Journal Article
Reference Number:
DEN-91-007397; EDB-91-137430
Resource Relation:
Journal Name: Beitraege aus der Plasmaphysik; (Germany); Journal Volume: 30:6
Subject:
70 PLASMA PHYSICS AND FUSION TECHNOLOGY; ELECTRIC DISCHARGES; SODIUM; COLOR; EFFICIENCY; EMISSION SPECTROSCOPY; LIGHT SOURCES; MEDIUM PRESSURE; PHOTOMETRY; PULSES; VERY HIGH TEMPERATURE; ALKALI METALS; ELEMENTS; METALS; OPTICAL PROPERTIES; ORGANOLEPTIC PROPERTIES; PHYSICAL PROPERTIES; RADIATION SOURCES; SPECTROSCOPY; 700103* - Fusion Energy- Plasma Research- Kinetics
OSTI ID:
5372634
Country of Origin:
Germany
Language:
English
Other Identifying Numbers:
Journal ID: ISSN 0005-8025; CODEN: BPPHA
Submitting Site:
DEN
Size:
Pages: 715-724
Announcement Date:

Journal Article:

Citation Formats

Guenther, K, Kloss, H G, Lehmann, T, Radtke, R, and Serick, F. Pulsed operation of high-pressure-sodium discharge lamps. Germany: N. p., 1990. Web.
Guenther, K, Kloss, H G, Lehmann, T, Radtke, R, & Serick, F. Pulsed operation of high-pressure-sodium discharge lamps. Germany.
Guenther, K, Kloss, H G, Lehmann, T, Radtke, R, and Serick, F. 1990. "Pulsed operation of high-pressure-sodium discharge lamps." Germany.
@misc{etde_5372634,
title = {Pulsed operation of high-pressure-sodium discharge lamps}
author = {Guenther, K, Kloss, H G, Lehmann, T, Radtke, R, and Serick, F}
abstractNote = {Results of spectral and photometric measurements are presented for pulsed operated high-pressure-sodium lamps. Choosing for the colour temperature a value of 3000 K, the output spectrum was optimized with respect to colour rendition and lamp efficacy taking the pulse parameters, the sodium mole fraction, and the cold spot temperature as quantities to be varied. For the nominal rating of 70 W a maximum lamp efficacy of 70 lm/W and a colour rendering index of 40 can be obtained. Further improvements of the colour rendition require an enhanced sodium vapour pressure which can be achieved by operating the lamp at rised cold spot temperature. (orig.).}
journal = {Beitraege aus der Plasmaphysik; (Germany)}
volume = {30:6}
journal type = {AC}
place = {Germany}
year = {1990}
month = {Jan}
}