Abstract

This document deals with flaw evaluation during in-service inspection. These flaws can be divided into two groups: defects originating from the manufacturing fabrication stage or service-induced flaws. These are mainly caused by high cycle thermal fatigue and are influenced by the presence of stress corrosion cracking mechanisms such as nozzles or pump shaft. (TEC).
Authors:
Yoon, K [1] 
  1. Babcock and Wilcox Co., Lynchburg, VA (United States). Nuclear Power Div.
Publication Date:
Dec 31, 1988
Product Type:
Conference
Report Number:
NEA-CSNI-R-91-14; CONF-8810570-
Reference Number:
SCA: 420200; 420500; PA: AIX-28:064489; EDB-97:126472; SN: 97001855200
Resource Relation:
Conference: Workshop on the complementary roles of fracture mechanics and non-destructive examination in the safety assessment of components, Wuerenlingen (Switzerland), 3-5 Oct 1988; Other Information: PBD: 1988; Related Information: Is Part Of The complementary roles of fracture mechanics and non-destructive examination in the safety assessment of components; PB: 526 p.
Subject:
42 ENGINEERING NOT INCLUDED IN OTHER CATEGORIES; IN-SERVICE INSPECTION; CRACK PROPAGATION; CRACKS; DEFECTS; ELASTICITY; FRACTURE MECHANICS; FRACTURES; NONDESTRUCTIVE ANALYSIS; NOZZLES; PRESSURE VESSELS; PUMPS; REACTOR VESSELS; STRESS CORROSION; THERMAL FATIGUE
OSTI ID:
529040
Research Organizations:
Nuclear Energy Agency, 75 - Paris (France). Committee on the Safety of Nuclear Installations
Country of Origin:
NEA
Language:
English
Other Identifying Numbers:
Other: ON: DE98600708; TRN: XN9600123064489
Availability:
INIS; OSTI as DE98600708
Submitting Site:
INIS
Size:
pp. 430-434
Announcement Date:

Citation Formats

Yoon, K. Component flaw evaluations. NEA: N. p., 1988. Web.
Yoon, K. Component flaw evaluations. NEA.
Yoon, K. 1988. "Component flaw evaluations." NEA.
@misc{etde_529040,
title = {Component flaw evaluations}
author = {Yoon, K}
abstractNote = {This document deals with flaw evaluation during in-service inspection. These flaws can be divided into two groups: defects originating from the manufacturing fabrication stage or service-induced flaws. These are mainly caused by high cycle thermal fatigue and are influenced by the presence of stress corrosion cracking mechanisms such as nozzles or pump shaft. (TEC).}
place = {NEA}
year = {1988}
month = {Dec}
}