Development of the EM tomography system. Part 2. Sensitivity studies of anomalous body by model studies; EM tomography system no kaihatsu. 2. Model kaiseki ni yoru ijotai no kando chosa kekka

Abstract

A model analysis was used to investigate sensitivity of a two-dimensional structure on a resistivity anomalous body by using an electromagnetic tomography system. The resistivity model handled a three-dimensional structure. The model was prepared as a pseudo two-dimensional model in which a low resistivity anomalous body with 1 ohm-m was incorporated that has a basic length of 1000 m in the Y-direction in a homogenous medium having 100 ohm-m. As a result of the analysis, the following matters were elucidated: if a low resistivity anomalous body is present in a shallow subsurface, its impact starts appearing from lower frequencies than when the anomalous body exists only at a greater depth; if a high resistivity anomalous body exists, the detection sensitivity is lower than for the low resistivity anomalous body, but the analysis would be possible by using the phase because the phase has made a greater change; the source TxZ shows a change from lower frequencies than for the source TxX, and the amount of change is greater, hence the detection sensitivity on an anomalous body may be said higher with the source TxZ; however, for the anomalous body in shallow subsurface, the source TxX is more effective since it  More>>
Authors:
Kumekawa, Y; Miura, Y; Takasugi, S; [1]  Arai, E [2] 
  1. GERD Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan)
  2. Metal Mining Agency of Japan, Tokyo (Japan)
Publication Date:
May 27, 1997
Product Type:
Conference
Report Number:
CONF-9705167-
Reference Number:
SCA: 440700; 580000; 990301; PA: NEDO-97:912250; EDB-97:120354; SN: 97001846542
Resource Relation:
Conference: 96. SEGJ conference, Butsuri tansa gakkai dai 96 kai (1997 nendo shunki) gakujutsu koenkai, Tokyo (Japan), 27-29 May 1997; Other Information: PBD: 27 May 1997; Related Information: Is Part Of Proceeding of the 96th (spring, fiscal 1997) SEGJ Conference; PB: 502 p.; Butsuri tansa gakkai dai 96 kai (1997 nendo shunki) gakujutsu koenkai koen ronbunshu
Subject:
44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; 58 GEOSCIENCES; 99 MATHEMATICS, COMPUTERS, INFORMATION SCIENCE, MANAGEMENT, LAW, MISCELLANEOUS; COMPUTERIZED TOMOGRAPHY; NUMERICAL ANALYSIS; MATHEMATICAL MODELS; THREE-DIMENSIONAL CALCULATIONS; ELECTROMAGNETIC SURVEYS; ELECTRIC CONDUCTIVITY; SENSITIVITY ANALYSIS; DEPTH; FREQUENCY DEPENDENCE; PHASE SHIFT
OSTI ID:
522651
Research Organizations:
Society of Exploration Geophysicists of Japan, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE97770262; TRN: 97:912250
Availability:
Available from The Society of Exploration Geophysicists of Japan, 2-18, Nakamagome 2-chome, Ota-ku, Tokyo, Japan; OSTI as DE97770262
Submitting Site:
NEDO
Size:
pp. 224-228
Announcement Date:

Citation Formats

Kumekawa, Y, Miura, Y, Takasugi, S, and Arai, E. Development of the EM tomography system. Part 2. Sensitivity studies of anomalous body by model studies; EM tomography system no kaihatsu. 2. Model kaiseki ni yoru ijotai no kando chosa kekka. Japan: N. p., 1997. Web.
Kumekawa, Y, Miura, Y, Takasugi, S, & Arai, E. Development of the EM tomography system. Part 2. Sensitivity studies of anomalous body by model studies; EM tomography system no kaihatsu. 2. Model kaiseki ni yoru ijotai no kando chosa kekka. Japan.
Kumekawa, Y, Miura, Y, Takasugi, S, and Arai, E. 1997. "Development of the EM tomography system. Part 2. Sensitivity studies of anomalous body by model studies; EM tomography system no kaihatsu. 2. Model kaiseki ni yoru ijotai no kando chosa kekka." Japan.
@misc{etde_522651,
title = {Development of the EM tomography system. Part 2. Sensitivity studies of anomalous body by model studies; EM tomography system no kaihatsu. 2. Model kaiseki ni yoru ijotai no kando chosa kekka}
author = {Kumekawa, Y, Miura, Y, Takasugi, S, and Arai, E}
abstractNote = {A model analysis was used to investigate sensitivity of a two-dimensional structure on a resistivity anomalous body by using an electromagnetic tomography system. The resistivity model handled a three-dimensional structure. The model was prepared as a pseudo two-dimensional model in which a low resistivity anomalous body with 1 ohm-m was incorporated that has a basic length of 1000 m in the Y-direction in a homogenous medium having 100 ohm-m. As a result of the analysis, the following matters were elucidated: if a low resistivity anomalous body is present in a shallow subsurface, its impact starts appearing from lower frequencies than when the anomalous body exists only at a greater depth; if a high resistivity anomalous body exists, the detection sensitivity is lower than for the low resistivity anomalous body, but the analysis would be possible by using the phase because the phase has made a greater change; the source TxZ shows a change from lower frequencies than for the source TxX, and the amount of change is greater, hence the detection sensitivity on an anomalous body may be said higher with the source TxZ; however, for the anomalous body in shallow subsurface, the source TxX is more effective since it is not subjected to a too great impact at a greater depth. 5 refs., 7 figs.}
place = {Japan}
year = {1997}
month = {May}
}