You need JavaScript to view this

Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV

Abstract

The author studied the response of an n-type silicon detector irradiated with 1 MeV neutrons at fluences ranging from 0.26x10{sup 13} to 11.19x10{sup 13} neutrons/cm{sup 2}. The response of the irradiated detector to {sup 241}Am alpha particles was measured. 13 refs., 7 figs.
Authors:
Roy, P [1] 
  1. Montreal Univ., PQ (Canada). Lab. de Physique Nucleaire
Publication Date:
Dec 31, 1993
Product Type:
Conference
Report Number:
INIS-CA-0009; CONF-9304317-
Reference Number:
SCA: 440200; PA: AIX-28:057472; EDB-97:120263; SN: 97001841687
Resource Relation:
Conference: 18. annual student conference CNA/CNS, Montreal (Canada), 2-3 Apr 1993; Other Information: PBD: 1993; Related Information: Is Part Of Proceedings of the 18. annual student conference CNA/CNS; Tye, P. [ed.]; PB: 239 p.
Subject:
44 INSTRUMENTATION, INCLUDING NUCLEAR AND PARTICLE DETECTORS; SI SEMICONDUCTOR DETECTORS; PHYSICAL RADIATION EFFECTS; ALPHA DETECTION; CHARGE COLLECTION; DOPED MATERIALS; EFFICIENCY; MEV RANGE 01-10; N-TYPE CONDUCTORS; NEUTRON BEAMS; NEUTRON FLUENCE; RESPONSE FUNCTIONS; SILICON
OSTI ID:
517114
Research Organizations:
Canadian Nuclear Society, Toronto, ON (Canada); Canadian Nuclear Association, Toronto, ON (Canada)
Country of Origin:
Canada
Language:
French
Other Identifying Numbers:
Other: ON: DE97638270; TRN: CA9700548057472
Availability:
INIS; OSTI as DE97638270
Submitting Site:
INIS
Size:
pp. 146-155
Announcement Date:
Sep 22, 1997

Citation Formats

Roy, P. Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV. Canada: N. p., 1993. Web.
Roy, P. Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV. Canada.
Roy, P. 1993. "Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV." Canada.
@misc{etde_517114,
title = {Study of the response of a silicon detector irradiated with 1 MeV neutrons; Etude de la reponse d`un detecteur Si irradie par des neutrons de 1 MeV}
author = {Roy, P}
abstractNote = {The author studied the response of an n-type silicon detector irradiated with 1 MeV neutrons at fluences ranging from 0.26x10{sup 13} to 11.19x10{sup 13} neutrons/cm{sup 2}. The response of the irradiated detector to {sup 241}Am alpha particles was measured. 13 refs., 7 figs.}
place = {Canada}
year = {1993}
month = {Dec}
}