Abstract
A {gamma}-ray absorption technique has been developed for measuring the axial distribution of the void fraction for high-temperature and high-pressure two-phase flows. The system is mounted on a moving platform driven by a high-power stepping motor. A personal computer (IBM AT) connected to a data acquisition system is used to control the displacement of the {gamma} source and detector, and to read the response of the detector. All the measurement procedures are carried out automatically by dedicated software developed for this purpose. (Author).
Citation Formats
Teyssedou, A, Aube, F, and Champagne, P.
Void fraction measurement system for high temperature flows.
United Kingdom: N. p.,
1992.
Web.
doi:10.1088/0957-0233/3/5/008.
Teyssedou, A, Aube, F, & Champagne, P.
Void fraction measurement system for high temperature flows.
United Kingdom.
https://doi.org/10.1088/0957-0233/3/5/008
Teyssedou, A, Aube, F, and Champagne, P.
1992.
"Void fraction measurement system for high temperature flows."
United Kingdom.
https://doi.org/10.1088/0957-0233/3/5/008.
@misc{etde_5126752,
title = {Void fraction measurement system for high temperature flows}
author = {Teyssedou, A, Aube, F, and Champagne, P}
abstractNote = {A {gamma}-ray absorption technique has been developed for measuring the axial distribution of the void fraction for high-temperature and high-pressure two-phase flows. The system is mounted on a moving platform driven by a high-power stepping motor. A personal computer (IBM AT) connected to a data acquisition system is used to control the displacement of the {gamma} source and detector, and to read the response of the detector. All the measurement procedures are carried out automatically by dedicated software developed for this purpose. (Author).}
doi = {10.1088/0957-0233/3/5/008}
journal = []
volume = {3:5}
journal type = {AC}
place = {United Kingdom}
year = {1992}
month = {May}
}
title = {Void fraction measurement system for high temperature flows}
author = {Teyssedou, A, Aube, F, and Champagne, P}
abstractNote = {A {gamma}-ray absorption technique has been developed for measuring the axial distribution of the void fraction for high-temperature and high-pressure two-phase flows. The system is mounted on a moving platform driven by a high-power stepping motor. A personal computer (IBM AT) connected to a data acquisition system is used to control the displacement of the {gamma} source and detector, and to read the response of the detector. All the measurement procedures are carried out automatically by dedicated software developed for this purpose. (Author).}
doi = {10.1088/0957-0233/3/5/008}
journal = []
volume = {3:5}
journal type = {AC}
place = {United Kingdom}
year = {1992}
month = {May}
}