Abstract
The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.
Kovalev, V P;
Diyankov, V S;
Kormilitsin, A I;
Lavrent`ev, B N
[1]
- All-Russian Research Inst. of Technical Physics, Snezhinsk (Russian Federation)
Citation Formats
Kovalev, V P, Diyankov, V S, Kormilitsin, A I, and Lavrent`ev, B N.
High-voltage many-pulses generator with inductive energy store and fuse.
Czech Republic: N. p.,
1996.
Web.
doi:10.1109/PPC.1997.674565.
Kovalev, V P, Diyankov, V S, Kormilitsin, A I, & Lavrent`ev, B N.
High-voltage many-pulses generator with inductive energy store and fuse.
Czech Republic.
https://doi.org/10.1109/PPC.1997.674565
Kovalev, V P, Diyankov, V S, Kormilitsin, A I, and Lavrent`ev, B N.
1996.
"High-voltage many-pulses generator with inductive energy store and fuse."
Czech Republic.
https://doi.org/10.1109/PPC.1997.674565.
@misc{etde_511258,
title = {High-voltage many-pulses generator with inductive energy store and fuse}
author = {Kovalev, V P, Diyankov, V S, Kormilitsin, A I, and Lavrent`ev, B N}
abstractNote = {The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.}
doi = {10.1109/PPC.1997.674565}
volume = {2}
place = {Czech Republic}
year = {1996}
month = {Dec}
}
title = {High-voltage many-pulses generator with inductive energy store and fuse}
author = {Kovalev, V P, Diyankov, V S, Kormilitsin, A I, and Lavrent`ev, B N}
abstractNote = {The high-voltage generator with inductive energy store and fuses as opening switch that generate series of powerful pulses is considered. This generator differs from the ordinary generator with inductive store by the cross-section of the series copper wires. The parameters of the wires are chosen based on empirical relations. The generation principle was tested on the two high-voltage generators with characteristic impedance 2.2 ohm, 4 ohm and with output voltages of 140 kV and 420 kV, respectively. Copper wires 0.1 to 0.23 mm in diameter were used. Series of 2 to 5 pulses of 100 to 300 ns duration, 400 to 1000 kV amplitude and 1 - 10 GW power were obtained. Pulses can be both the same and different. Two successive bremsstrahlung radiation pulses were obtain on the EMIR-M and IGUR-3 devices. Series power megavolt pulses can be generated with a power exceeding 10{sup 11} W, pulse duration of 10{sup -3} to 10{sup -6} s, and time interval between them 10{sup -7} to 10{sup -5} s. (author). 4 figs., 2 refs.}
doi = {10.1109/PPC.1997.674565}
volume = {2}
place = {Czech Republic}
year = {1996}
month = {Dec}
}