Following postulated events of a LOCA, the passive Containment Cooling System (PCCS) uses dry air to transfer the residual heat by natural circulation. The air flow path, designed between the steel reactor containment hot shell and the concrete shield building, creates an open thermosyphon. The purpose of this inherently safe process is to assure the long term steady-state cooling of the nuclear core after an emergency shutdown (authors).
Authors:
Harari, R; Weis, Y; Barnea, Y [1] 
  1. Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev
Publication Date:
Dec 01, 1996
Product Type:
Conference
Report Number:
INIS-mf-15507; CONF-961252-
Reference Number:
SCA: 220100; PA: AIX-28:023672; EDB-97:072410; SN: 97001788820
Resource Relation:
Conference: 19. conference of the Israel Nuclear Societies, Herzliya (Israel), 9-10 Dec 1996; Other Information: PBD: Dec 1996; Related Information: Is Part Of Program and book of abstracts; PB: 149 p.
Subject:
22 NUCLEAR REACTOR TECHNOLOGY; WESTINGHOUSE STANDARD REACTOR; DESIGN BASIS ACCIDENTS; COMPUTERIZED SIMULATION; ECCS; GASES; REACTOR CORES; REACTOR SAFETY EXPERIMENTS
OSTI ID:
475945
Research Organizations:
Israel Nuclear Society, Yavne (Israel)
Country of Origin:
Israel
Language:
English
Other Identifying Numbers:
Other: ON: DE97616259; TRN: IL9606195023672
Availability:
INIS; OSTI as DE97616259
Submitting Site:
INIS
Size:
pp. 1-4
Announcement Date:

Citation Formats

Harari, R, Weis, Y, and Barnea, Y. Thermohydraulic modeling of the dry air passive containment cooling system process in the Westinghouse AP-600 ALWR. Israel: N. p., 1996. Web.
Harari, R, Weis, Y, & Barnea, Y. Thermohydraulic modeling of the dry air passive containment cooling system process in the Westinghouse AP-600 ALWR. Israel.
Harari, R, Weis, Y, and Barnea, Y. 1996. "Thermohydraulic modeling of the dry air passive containment cooling system process in the Westinghouse AP-600 ALWR." Israel.
@misc{etde_475945,
title = {Thermohydraulic modeling of the dry air passive containment cooling system process in the Westinghouse AP-600 ALWR}
author = {Harari, R, Weis, Y, and Barnea, Y}
abstractNote = {Following postulated events of a LOCA, the passive Containment Cooling System (PCCS) uses dry air to transfer the residual heat by natural circulation. The air flow path, designed between the steel reactor containment hot shell and the concrete shield building, creates an open thermosyphon. The purpose of this inherently safe process is to assure the long term steady-state cooling of the nuclear core after an emergency shutdown (authors).}
place = {Israel}
year = {1996}
month = {Dec}
}