Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka

Abstract

For the effective utilization of solar energy at houses, a heating system using an air hybrid collector (capable of simultaneously performing heat collection and photovoltaic power generation). As the specimen house, a wooden house of a total floor area of 120m{sup 2} was simulated. Collected air is fanned into a crushed stone heat accumulator (capable of storing one day`s collection) or into a living room. The output of solar cell arrays is put into a heat pump (capable of handling a maximum hourly load of 36,327kJ/h) via an inverter so as to drive the fan (corresponding to average insolation on the heat collecting plate of 10.7MJ/hm{sup 2} and heat collecting efficiency of 40%), and shortage in power if any is supplied from the system interconnection. A hybrid collector, as compared with the conventional air collector, is lower in thermal efficiency but the merit that it exhibits with respect to power generation is far greater than what is needed to counterbalance the demerit. When the hybrid system is in heating operation, there is an ideal heat cycle of collection, accumulation, and radiation when the load is light, but the balance between accumulation and radiation is disturbed when the load is heavy.  More>>
Authors:
Yoshinaga, M; Okumiya, M [1] 
  1. Nagoya University, Nagoya (Japan)
Publication Date:
Oct 27, 1996
Product Type:
Conference
Report Number:
CONF-9610295-
Reference Number:
SCA: 320106; 140600; 140900; PA: NEDO-96:915502; EDB-97:073063; SN: 97001783046
Resource Relation:
Conference: JSES/JWEA joint conference (1996), 1996 nendo nihon taiyo energy gakkai nihon furyoku energy kyokai godo kenkyu happyokai, Yamagata (Japan), 31 Oct - 1 Nov 1996; Other Information: PBD: 27 Oct 1996; Related Information: Is Part Of Proceedings of JSES/JWEA Joint Conference (1996); PB: 406 p.; Taiyo/furyoku energy koen ronbunshu (1996)
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 14 SOLAR ENERGY; HYBRID SYSTEMS; SOLAR COLLECTORS; PHOTOVOLTAIC POWER PLANTS; HOUSES; SPACE HEATING; AIR FLOW; ROCK BEDS; WOOD; BLOWERS; SOLAR CELL ARRAYS; HEAT PUMPS; INTERCONNECTED POWER SYSTEMS
OSTI ID:
472795
Research Organizations:
Japan Solar Energy Society, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE97744185; TRN: 96:915502
Availability:
Available from Japan Solar Energy Society, 44-14, Yoyogi 2-chome, Shibuya-ku, Tokyo, Japan; OSTI as DE97744185
Submitting Site:
NEDO
Size:
pp. 289-292
Announcement Date:
Jun 03, 1997

Citation Formats

Yoshinaga, M, and Okumiya, M. Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka. Japan: N. p., 1996. Web.
Yoshinaga, M, & Okumiya, M. Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka. Japan.
Yoshinaga, M, and Okumiya, M. 1996. "Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka." Japan.
@misc{etde_472795,
title = {Hybrid utilization of solar energy. Part 2. Performance analyses of heating system with air hybrid collector; Taiyo energy no hybrid riyo ni kansuru kenkyu. 2. Kuki shunetsu hybrid collector wo mochiita danbo system no seino hyoka}
author = {Yoshinaga, M, and Okumiya, M}
abstractNote = {For the effective utilization of solar energy at houses, a heating system using an air hybrid collector (capable of simultaneously performing heat collection and photovoltaic power generation). As the specimen house, a wooden house of a total floor area of 120m{sup 2} was simulated. Collected air is fanned into a crushed stone heat accumulator (capable of storing one day`s collection) or into a living room. The output of solar cell arrays is put into a heat pump (capable of handling a maximum hourly load of 36,327kJ/h) via an inverter so as to drive the fan (corresponding to average insolation on the heat collecting plate of 10.7MJ/hm{sup 2} and heat collecting efficiency of 40%), and shortage in power if any is supplied from the system interconnection. A hybrid collector, as compared with the conventional air collector, is lower in thermal efficiency but the merit that it exhibits with respect to power generation is far greater than what is needed to counterbalance the demerit. When the hybrid system is in heating operation, there is an ideal heat cycle of collection, accumulation, and radiation when the load is light, but the balance between accumulation and radiation is disturbed when the load is heavy. 4 refs., 8 figs., 3 tabs.}
place = {Japan}
year = {1996}
month = {Oct}
}