You need JavaScript to view this

Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite

Abstract

A report was made on the measurement of data and the results of the analysis at 14 sites of photovoltaic power generation facilities operated under system interconnection by Tokyo Electric Power Company. This type of system is provided in 40 sites as of the end of fiscal 1995, generating 479kw. The items measured were the generated electric energy at all 14 sites, and the quantity of solar radiation, outside air temperature, panel temperature, etc., at limited sites; and the capacity of each equipment, azimuth and inclination of the panel were also recorded simultaneously. Hourly values were used for the analysis. Five minute values were utilized, however, in the examination of the cause of lowered output and in the situation recognition of the influence of the shade or the change of weather. The utilization factor of the facilities was in the average 10.8% in fiscal 1994 and 10.7% in fiscal 1995. The factor decreased slightly unless the panel azimuth faced due south. The utilization factor at the panel inclination of 35 degrees and 45 degrees showed both 10.4% through the year making no difference. The system seemed to show no overwhelming possibilities in coping with electric power demand. The reason was  More>>
Authors:
Fukuda, H; Itokawa, K [1] 
  1. Tokyo Electric Power Co. Inc., Tokyo (Japan)
Publication Date:
Oct 27, 1996
Product Type:
Miscellaneous
Report Number:
CONF-9610295-
Reference Number:
SCA: 140600; PA: NEDO-96:915428; EDB-97:071949; SN: 97001782971
Resource Relation:
Conference: JSES/JWEA joint conference (1996), 1996 nendo nihon taiyo energy gakkai nihon furyoku energy kyokai godo kenkyu happyokai, Yamagata (Japan), 31 Oct - 1 Nov 1996; Other Information: PBD: 27 Oct 1996; Related Information: Is Part Of Proceedings of JSES/JWEA Joint Conference (1996); PB: 406 p.; Taiyo/furyoku energy koen ronbunshu (1996)
Subject:
14 SOLAR ENERGY; JAPAN; ELECTRIC POWER INDUSTRY; PHOTOVOLTAIC POWER PLANTS; INTERCONNECTED POWER SYSTEMS; EXPERIMENTAL DATA; DATA ANALYSIS; POWER DEMAND; OFF-PEAK POWER; RELIABILITY; SOLAR CELL ARRAYS; SITE CHARACTERIZATION; INSOLATION; INCIDENCE ANGLE
OSTI ID:
472721
Research Organizations:
Japan Solar Energy Society, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE97744185; TRN: 96:915428
Availability:
Available from Japan Solar Energy Society, 44-14, Yoyogi 2-chome, Shibuya-ku, Tokyo, Japan; OSTI as DE97744185
Submitting Site:
NEDO
Size:
pp. 1-4
Announcement Date:
Jun 03, 1997

Citation Formats

Fukuda, H, and Itokawa, K. Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite. Japan: N. p., 1996. Web.
Fukuda, H, & Itokawa, K. Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite. Japan.
Fukuda, H, and Itokawa, K. 1996. "Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite." Japan.
@misc{etde_472721,
title = {Results of photovoltaic power generation system operation in Tokyo Electric Power Company; Tokyo Denryoku ni okeru taiyoko hatsuden setsubi no unten jisseki ni tsuite}
author = {Fukuda, H, and Itokawa, K}
abstractNote = {A report was made on the measurement of data and the results of the analysis at 14 sites of photovoltaic power generation facilities operated under system interconnection by Tokyo Electric Power Company. This type of system is provided in 40 sites as of the end of fiscal 1995, generating 479kw. The items measured were the generated electric energy at all 14 sites, and the quantity of solar radiation, outside air temperature, panel temperature, etc., at limited sites; and the capacity of each equipment, azimuth and inclination of the panel were also recorded simultaneously. Hourly values were used for the analysis. Five minute values were utilized, however, in the examination of the cause of lowered output and in the situation recognition of the influence of the shade or the change of weather. The utilization factor of the facilities was in the average 10.8% in fiscal 1994 and 10.7% in fiscal 1995. The factor decreased slightly unless the panel azimuth faced due south. The utilization factor at the panel inclination of 35 degrees and 45 degrees showed both 10.4% through the year making no difference. The system seemed to show no overwhelming possibilities in coping with electric power demand. The reason was that deviation existed for 2 hours or so in the peak and that reliability was low as basic power facilities. However, it was determined that the system be continuously examined in future. 9 figs., 1 tab.}
place = {Japan}
year = {1996}
month = {Oct}
}