The erect of earth fault protection practices on the frequency of outages in MV lines

Abstract

In this presentation different methods to improve extinction of the earth fault arc in the medium voltage network and reducing the short interruptions to customers are discussed. First the disadvantages of the rapid autoreclosing functions to customers are studied. Then the influence of the star point impedance to the number of short interruptions is discussed. Finally, the feasibility of utilizing shunt circuit-breakers in the Finnish MV networks to extinguish the arc, is studied
Authors:
Lakervi, E; Nikander, A [1] 
  1. Tampere Univ. of Technology (Finland)
Publication Date:
Dec 31, 1996
Product Type:
Technical Report
Report Number:
VTT-TIED-1735
Reference Number:
SCA: 240200; 296000; PA: FI-97:003313; EDB-97:066338; SN: 97001773826
Resource Relation:
Other Information: DN: EDISON Research Programme; PBD: 1996; Related Information: Is Part Of EDISON - research programme on electricity distribution automation 1993-1997. Interim report 1995; Lehtonen, M. [ed.] [VTT Energy, Espoo (Finland). Energy Systems]; PB: 136 p.
Subject:
24 POWER TRANSMISSION AND DISTRIBUTION; 29 ENERGY PLANNING AND POLICY; POWER DISTRIBUTION SYSTEMS; ELECTRICAL FAULTS; ELECTRIC GROUNDS; ELECTRIC POWER; OUTAGES; FREQUENCY DEPENDENCE; CIRCUIT BREAKERS; RELIABILITY
OSTI ID:
468468
Research Organizations:
Technical Research Centre of Finland, Espoo (Finland)
Country of Origin:
Finland
Language:
English
Other Identifying Numbers:
Other: ON: DE97740685; ISBN 951-38-4890-6; TRN: FI9703313
Availability:
OSTI as DE97740685
Submitting Site:
FI
Size:
pp. 29-33
Announcement Date:
May 23, 1997

Citation Formats

Lakervi, E, and Nikander, A. The erect of earth fault protection practices on the frequency of outages in MV lines. Finland: N. p., 1996. Web.
Lakervi, E, & Nikander, A. The erect of earth fault protection practices on the frequency of outages in MV lines. Finland.
Lakervi, E, and Nikander, A. 1996. "The erect of earth fault protection practices on the frequency of outages in MV lines." Finland.
@misc{etde_468468,
title = {The erect of earth fault protection practices on the frequency of outages in MV lines}
author = {Lakervi, E, and Nikander, A}
abstractNote = {In this presentation different methods to improve extinction of the earth fault arc in the medium voltage network and reducing the short interruptions to customers are discussed. First the disadvantages of the rapid autoreclosing functions to customers are studied. Then the influence of the star point impedance to the number of short interruptions is discussed. Finally, the feasibility of utilizing shunt circuit-breakers in the Finnish MV networks to extinguish the arc, is studied}
place = {Finland}
year = {1996}
month = {Dec}
}