Abstract
Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.
Abdel-Rehim, F;
Said, F I.A.;
Abdel-Fattah, A A
[1]
- National Centre for Radiation Research and Technology, Atomic Energy Athority, P.O.Box 29 Nasr City, Cairo (Egypt)
Citation Formats
Abdel-Rehim, F, Said, F I.A., and Abdel-Fattah, A A.
Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2.
Egypt: N. p.,
1996.
Web.
Abdel-Rehim, F, Said, F I.A., & Abdel-Fattah, A A.
Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2.
Egypt.
Abdel-Rehim, F, Said, F I.A., and Abdel-Fattah, A A.
1996.
"Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2."
Egypt.
@misc{etde_456151,
title = {Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2}
author = {Abdel-Rehim, F, Said, F I.A., and Abdel-Fattah, A A}
abstractNote = {Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.}
place = {Egypt}
year = {1996}
month = {Mar}
}
title = {Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2}
author = {Abdel-Rehim, F, Said, F I.A., and Abdel-Fattah, A A}
abstractNote = {Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.}
place = {Egypt}
year = {1996}
month = {Mar}
}