You need JavaScript to view this

Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4

Abstract

Phantom of tissue equivalent material with and without bone was used measuring depth dose distribution of gamma-rays from californium-252 source. The source was positioned at center of perspex walled phantom. Depth dose measurements were recorded for X, Y and Z planes at different distances from source. TLD 700 was used for measuring the dose distribution. Results indicate that implantation of bone in tissue equivalent medium cause changes in the gamma depth dose distribution which varies according to variation in bone geometry. 9 figs.
Authors:
Fadel, M A; El-Fiki, M A; Eissa, H M; Abdel-Hafez, A; Naguib, S H [1] 
  1. National Institute of Standards, Cairo (Egypt)
Publication Date:
Mar 01, 1996
Product Type:
Miscellaneous
Report Number:
INIS-EG-002; CONF-960316-
Reference Number:
SCA: 070207; PA: AIX-28:030592; EDB-97:053993; SN: 97001765242
Resource Relation:
Conference: 6. conference of nuclear sciences and applications, Cairo (Egypt), 15-20 Mar 1996; Other Information: PBD: Mar 1996; Related Information: Is Part Of Proceedings of the sixth conference of nuclear sciences and applications. Vol. 1-4; PB: 1760 p.
Subject:
07 ISOTOPE AND RADIATION SOURCE TECHNOLOGY; TISSUE-EQUIVALENT MATERIALS; CALIFORNIUM 252; DEPTH DOSE DISTRIBUTIONS; EXPERIMENTAL DATA; GAMMA RADIATION; RADIATION SOURCE IMPLANTS
OSTI ID:
456034
Research Organizations:
Atomic Energy Establishment, Cairo (Egypt); Egyptian Society of Nuclear Sciences and Applications, Cairo (Egypt)
Country of Origin:
Egypt
Language:
English
Other Identifying Numbers:
Other: ON: DE97620041; TRN: EG9601842030592
Availability:
INIS; OSTI as DE97620041
Submitting Site:
INIS
Size:
pp. 208
Announcement Date:

Citation Formats

Fadel, M A, El-Fiki, M A, Eissa, H M, Abdel-Hafez, A, and Naguib, S H. Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4. Egypt: N. p., 1996. Web.
Fadel, M A, El-Fiki, M A, Eissa, H M, Abdel-Hafez, A, & Naguib, S H. Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4. Egypt.
Fadel, M A, El-Fiki, M A, Eissa, H M, Abdel-Hafez, A, and Naguib, S H. 1996. "Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4." Egypt.
@misc{etde_456034,
title = {Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4}
author = {Fadel, M A, El-Fiki, M A, Eissa, H M, Abdel-Hafez, A, and Naguib, S H}
abstractNote = {Phantom of tissue equivalent material with and without bone was used measuring depth dose distribution of gamma-rays from californium-252 source. The source was positioned at center of perspex walled phantom. Depth dose measurements were recorded for X, Y and Z planes at different distances from source. TLD 700 was used for measuring the dose distribution. Results indicate that implantation of bone in tissue equivalent medium cause changes in the gamma depth dose distribution which varies according to variation in bone geometry. 9 figs.}
place = {Egypt}
year = {1996}
month = {Mar}
}