Abstract
The base metal Crack Opening Displacement (COD) specimens of the irradiation-induced embrittlement surveillance programme in Loviisa 1 revealed an anomalous behaviour of K{sub JC} compared to the Charpy-V results and to expected results according to standards: about 20% of the COD specimens showed an exceptionally low fracture toughness. Abnormal test specimens were analyzed through fractography, metallography and repeated tests using reconstitution technique: the anomalous behaviour appears to be caused by incorrect pre-fatigue cracking of base metal COD specimens. 7 refs., 9 figs.
Ahistrand, R
[1]
- Imatran Voima Oy (IVO), Helsinki (Finland)
Citation Formats
Ahistrand, R.
Anomalous fracture toughness of irradiated Cr-MoV - Reactor pressure vessel steel.
NEA: N. p.,
1993.
Web.
Ahistrand, R.
Anomalous fracture toughness of irradiated Cr-MoV - Reactor pressure vessel steel.
NEA.
Ahistrand, R.
1993.
"Anomalous fracture toughness of irradiated Cr-MoV - Reactor pressure vessel steel."
NEA.
@misc{etde_455781,
title = {Anomalous fracture toughness of irradiated Cr-MoV - Reactor pressure vessel steel}
author = {Ahistrand, R}
abstractNote = {The base metal Crack Opening Displacement (COD) specimens of the irradiation-induced embrittlement surveillance programme in Loviisa 1 revealed an anomalous behaviour of K{sub JC} compared to the Charpy-V results and to expected results according to standards: about 20% of the COD specimens showed an exceptionally low fracture toughness. Abnormal test specimens were analyzed through fractography, metallography and repeated tests using reconstitution technique: the anomalous behaviour appears to be caused by incorrect pre-fatigue cracking of base metal COD specimens. 7 refs., 9 figs.}
place = {NEA}
year = {1993}
month = {Dec}
}
title = {Anomalous fracture toughness of irradiated Cr-MoV - Reactor pressure vessel steel}
author = {Ahistrand, R}
abstractNote = {The base metal Crack Opening Displacement (COD) specimens of the irradiation-induced embrittlement surveillance programme in Loviisa 1 revealed an anomalous behaviour of K{sub JC} compared to the Charpy-V results and to expected results according to standards: about 20% of the COD specimens showed an exceptionally low fracture toughness. Abnormal test specimens were analyzed through fractography, metallography and repeated tests using reconstitution technique: the anomalous behaviour appears to be caused by incorrect pre-fatigue cracking of base metal COD specimens. 7 refs., 9 figs.}
place = {NEA}
year = {1993}
month = {Dec}
}