Abstract
One of the key objectives of HTTR is to demonstrate effectiveness of high-temperature nuclear heat utilization system. Prior to connecting a heat utilization system to HTTR, an out-pile demonstration test is indispensable for the development of experimental apparatuses, operational control and safety technology, and verification of the analysis code of safety assessment. For the first heat utilization system of HTTR, design of the hydrogen production system by steam reforming is going on. We have proposed the out-pile demonstration test plan of the heat utilization system and conducted preliminary design of the test facility. In this report, design of the steam reformer, which is the principal component of the test facility, is described. In the course of the design, two types of reformers are considered. The one reformer contains three reactor tubes and the other contains one reactor tube to reduce the construction cost of the test facility. We have selected the steam reformer operational conditions and structural specifications by analyzing the steam reforming characteristics and component structural strength for each type of reformer. (author)
Haga, Katsuhiro;
Hino, Ryutaro;
Inagaki, Yosiyuki;
Hata, Kazuhiko;
Aita, Hideki;
Sekita, Kenji;
Nishihara, Tetsuo;
Sudo, Yukio;
[1]
Yamada, Seiya
- Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment
Citation Formats
Haga, Katsuhiro, Hino, Ryutaro, Inagaki, Yosiyuki, Hata, Kazuhiko, Aita, Hideki, Sekita, Kenji, Nishihara, Tetsuo, Sudo, Yukio, and Yamada, Seiya.
Preliminary design of steam reformer in out-pile demonstration test facility for HTTR heat utilization system.
Japan: N. p.,
1996.
Web.
Haga, Katsuhiro, Hino, Ryutaro, Inagaki, Yosiyuki, Hata, Kazuhiko, Aita, Hideki, Sekita, Kenji, Nishihara, Tetsuo, Sudo, Yukio, & Yamada, Seiya.
Preliminary design of steam reformer in out-pile demonstration test facility for HTTR heat utilization system.
Japan.
Haga, Katsuhiro, Hino, Ryutaro, Inagaki, Yosiyuki, Hata, Kazuhiko, Aita, Hideki, Sekita, Kenji, Nishihara, Tetsuo, Sudo, Yukio, and Yamada, Seiya.
1996.
"Preliminary design of steam reformer in out-pile demonstration test facility for HTTR heat utilization system."
Japan.
@misc{etde_452783,
title = {Preliminary design of steam reformer in out-pile demonstration test facility for HTTR heat utilization system}
author = {Haga, Katsuhiro, Hino, Ryutaro, Inagaki, Yosiyuki, Hata, Kazuhiko, Aita, Hideki, Sekita, Kenji, Nishihara, Tetsuo, Sudo, Yukio, and Yamada, Seiya}
abstractNote = {One of the key objectives of HTTR is to demonstrate effectiveness of high-temperature nuclear heat utilization system. Prior to connecting a heat utilization system to HTTR, an out-pile demonstration test is indispensable for the development of experimental apparatuses, operational control and safety technology, and verification of the analysis code of safety assessment. For the first heat utilization system of HTTR, design of the hydrogen production system by steam reforming is going on. We have proposed the out-pile demonstration test plan of the heat utilization system and conducted preliminary design of the test facility. In this report, design of the steam reformer, which is the principal component of the test facility, is described. In the course of the design, two types of reformers are considered. The one reformer contains three reactor tubes and the other contains one reactor tube to reduce the construction cost of the test facility. We have selected the steam reformer operational conditions and structural specifications by analyzing the steam reforming characteristics and component structural strength for each type of reformer. (author)}
place = {Japan}
year = {1996}
month = {Nov}
}
title = {Preliminary design of steam reformer in out-pile demonstration test facility for HTTR heat utilization system}
author = {Haga, Katsuhiro, Hino, Ryutaro, Inagaki, Yosiyuki, Hata, Kazuhiko, Aita, Hideki, Sekita, Kenji, Nishihara, Tetsuo, Sudo, Yukio, and Yamada, Seiya}
abstractNote = {One of the key objectives of HTTR is to demonstrate effectiveness of high-temperature nuclear heat utilization system. Prior to connecting a heat utilization system to HTTR, an out-pile demonstration test is indispensable for the development of experimental apparatuses, operational control and safety technology, and verification of the analysis code of safety assessment. For the first heat utilization system of HTTR, design of the hydrogen production system by steam reforming is going on. We have proposed the out-pile demonstration test plan of the heat utilization system and conducted preliminary design of the test facility. In this report, design of the steam reformer, which is the principal component of the test facility, is described. In the course of the design, two types of reformers are considered. The one reformer contains three reactor tubes and the other contains one reactor tube to reduce the construction cost of the test facility. We have selected the steam reformer operational conditions and structural specifications by analyzing the steam reforming characteristics and component structural strength for each type of reformer. (author)}
place = {Japan}
year = {1996}
month = {Nov}
}