Abstract
The Hair conditioner, which belongs to the group of cosmetic products Dr Miyares Cao, was artificially contaminated, kept at different values of temperature (-20 {sup oC}, 0{sup oC} and +20{sup oC}) and irradiated to different doses (6, 10, 12, 15, 20, 25 and 30 kGy) and 25 {sup oC} for studying the effect of gamma radiation on it and the possibility of use of this technology for its decontamination. The radiobiological parameters of the contaminator and the quality of irradiated products were determined. Was conclude that the product maintain its organolepthics characteristics and others quality parameters after irradiated to 20 kGy and +20{sup oC} of temperature before irradiation. Finally, the decontamination of studied product was obtained by means its irradiation to 16.2 kGy.
Romay, Z;
Otero, I;
Chavez, A;
[1]
Torriente, I
[2]
- Centro de Estudios Aplicados al Desarrollo Nuclear (CEADEN), La Habana (Cuba)
- Centro de Histoterapia Placentaria, La Habana (Cuba)
Citation Formats
Romay, Z, Otero, I, Chavez, A, and Torriente, I.
Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar.
Cuba: N. p.,
1996.
Web.
Romay, Z, Otero, I, Chavez, A, & Torriente, I.
Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar.
Cuba.
Romay, Z, Otero, I, Chavez, A, and Torriente, I.
1996.
"Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar."
Cuba.
@misc{etde_424811,
title = {Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar}
author = {Romay, Z, Otero, I, Chavez, A, and Torriente, I}
abstractNote = {The Hair conditioner, which belongs to the group of cosmetic products Dr Miyares Cao, was artificially contaminated, kept at different values of temperature (-20 {sup oC}, 0{sup oC} and +20{sup oC}) and irradiated to different doses (6, 10, 12, 15, 20, 25 and 30 kGy) and 25 {sup oC} for studying the effect of gamma radiation on it and the possibility of use of this technology for its decontamination. The radiobiological parameters of the contaminator and the quality of irradiated products were determined. Was conclude that the product maintain its organolepthics characteristics and others quality parameters after irradiated to 20 kGy and +20{sup oC} of temperature before irradiation. Finally, the decontamination of studied product was obtained by means its irradiation to 16.2 kGy.}
place = {Cuba}
year = {1996}
month = {Dec}
}
title = {Radio decontamination of hair conditioner for capillary ammniotherapy; Radiodescontaminacion del acondicionador del cabello destinado a la amnioterapia capilar}
author = {Romay, Z, Otero, I, Chavez, A, and Torriente, I}
abstractNote = {The Hair conditioner, which belongs to the group of cosmetic products Dr Miyares Cao, was artificially contaminated, kept at different values of temperature (-20 {sup oC}, 0{sup oC} and +20{sup oC}) and irradiated to different doses (6, 10, 12, 15, 20, 25 and 30 kGy) and 25 {sup oC} for studying the effect of gamma radiation on it and the possibility of use of this technology for its decontamination. The radiobiological parameters of the contaminator and the quality of irradiated products were determined. Was conclude that the product maintain its organolepthics characteristics and others quality parameters after irradiated to 20 kGy and +20{sup oC} of temperature before irradiation. Finally, the decontamination of studied product was obtained by means its irradiation to 16.2 kGy.}
place = {Cuba}
year = {1996}
month = {Dec}
}