Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino

Abstract

When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is  More>>
Authors:
Ito, S; Miura, N; [1]  Uchikawa, Y [2] 
  1. Kanagawa Institute of Technology, Kanagawa (Japan)
  2. Kubota Corp., Osaka (Japan)
Publication Date:
Nov 25, 1997
Product Type:
Conference
Report Number:
ETDE/JP-98753622; CONF-9711143-
Reference Number:
SCA: 320105; 140900; PA: JP-98:0G1087; SN: 98001983490
Resource Relation:
Conference: 1997 JSES/JWEA joint conference, Taiyo/furyoku energy koen, Aichi (Japan), 28-29 Nov 1997; Other Information: PBD: 25 Nov 1997; Related Information: Is Part Of Proceedings of JSES/JWEA Joint Conference (1997); PB: 454 p.; Taiyo/Furyoku energy koen ronbunshu (1997)
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 14 SOLAR ENERGY; WATER SOURCE HEAT PUMPS; AIR SOURCE HEAT PUMPS; COOLING SYSTEMS; PERFORMANCE; VAPOR CONDENSERS; AIR; WATER; COEFFICIENT OF PERFORMANCE
OSTI ID:
366057
Research Organizations:
Japan Solar Energy Society, Tokyo (Japan)
Country of Origin:
Japan
Language:
Japanese
Other Identifying Numbers:
Other: ON: DE98753622; TRN: JN98G1087
Availability:
Available from Japan Solar Energy Society, 44-14, Yoyogi 2-chome, Shibuya-ku, Tokyo, Japan; OSTI as DE98753622
Submitting Site:
NEDO
Size:
pp. 285-288
Announcement Date:

Citation Formats

Ito, S, Miura, N, and Uchikawa, Y. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino. Japan: N. p., 1997. Web.
Ito, S, Miura, N, & Uchikawa, Y. Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino. Japan.
Ito, S, Miura, N, and Uchikawa, Y. 1997. "Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino." Japan.
@misc{etde_366057,
title = {Heat pump using dual heat sources of air and water. Performance in cooling mode; Mizu kuki ryonetsugen heat pump no kenkyu. Reibo unten ni okeru seino}
author = {Ito, S, Miura, N, and Uchikawa, Y}
abstractNote = {When a heat pump is used for cooling purpose, it is possible to utilize different kinds of waste water as high-heat sources. However, these heat sources would have their temperatures vary with seasons and time in a day. Therefore, a discussion was given on performance of a heat pump when water and air heat sources are used for condensers during cooling operation independently, in series and in parallel, respectively. The air condenser shows an equivalent COP as compared with the water condenser when air temperature is lower by about 8 degC than water temperature. At the same heat source temperature, the COP for the water condenser indicated a value higher by about 0.6 than the case of the air condenser. A method to use condensers in parallel experiences little contribution from the air heat source, and performance of the heat pump decreases below the case of using the water heat source independently when the air heat source temperature becomes higher than that of the water heat source. In the case of series use in which a water condenser is installed in front and an air condenser in rear, its effect is exhibited when temperature in the air heat source is lower than that in the water heat source. Better performance was shown than in operating the water heat source independently. 2 refs., 9 figs.}
place = {Japan}
year = {1997}
month = {Nov}
}