You need JavaScript to view this

The Panama fossil power plants generation system: Atmospheric pollution, general and legal aspects; El sistema de generacion termoelectrico en Panama: Contaminacion atmosferica, aspectos generales y legales

Abstract

The Thermal electric energy resource of Panama is administered by four Regional Managements and a group of Regional Systems comprising the fossil power plants supplying electric energy to the country`s marginal areas. The characteristics of the different fuels used in these fossil power plants, the results of the assessment of the polluting particles and sulfur and nitrogen oxides are presented. Finally, the alleviation measures and the environmental legislation implanted in these power plants are also presented [Espanol] El parque termico de Panama es administrado por cuatro Gerencias Regionales y un conjunto de Sistemas Regionales que comprenden las plantas termicas de menor capacidad destinadas a suplir de energia a las areas marginadas del pais. Se presentan las caracteristicas de los diferentes combustibles utilizados en estas unidades termicas; los resultados de las mediciones de particulas contaminantes y de oxidos de azufre y oxidos de nitrogeno. Por ultimo se presentan las medidas de mitigacion y legislacion ambiental implantadas en estas centrales termoelectricas
Authors:
Milciades, Concepcion [1] 
  1. Instituto de Recursos Hidraulicos y Electrificacion, (Panama)
Publication Date:
Dec 31, 1996
Product Type:
Miscellaneous
Report Number:
CONF-9606416-
Reference Number:
SCA: 200500; PA: MX-99:000057; EDB-99:044918; SN: 99002078197
Resource Relation:
Conference: Foreseeing techniques and control of emissions in thermal power plants, Control y tecnicas de prevision de las emisiones de centrales termoelectricas, Cuernavaca (Mexico), 24-28 Jun 1996; Other Information: PBD: 1996; Related Information: Is Part Of Foreseeing techniques and control of emissions in thermal power plants; Saldana, R.; Morales, F.; Urrutia, M. [eds.] [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)]; PB: 218 p.; Control y tecnicas de prevision de las emisiones de centrales termoelectricas
Subject:
20 FOSSIL-FUELED POWER PLANTS; THERMAL POWER PLANTS; POWER GENERATION; ENVIRONMENTAL IMPACTS; POLLUTION CONTROL; AIR POLLUTION CONTROL; THERMAL POLLUTION; ENVIRONMENTAL QUALITY; ENVIRONMENTAL POLICY; ENVIRONMENTAL IMPACT STATEMENTS; POLLUTION LAWS; POLLUTANTS; FUELS; PANAMA; NUMERICAL DATA
Sponsoring Organizations:
Programa de Cooperacion Internacional de Ciencia, Investigacion y Desarrollo de la Union Europea, (CEC); Instituto de Investigaciones Electricas (IIE), (Mexico)
OSTI ID:
335145
Research Organizations:
Instituto de Investigaciones Electricas (IIE), (Mexico)
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE99735356; TRN: MX9900057
Availability:
OSTI as DE99735356
Submitting Site:
MX
Size:
pp. 183-192
Announcement Date:
May 11, 1999

Citation Formats

Milciades, Concepcion. The Panama fossil power plants generation system: Atmospheric pollution, general and legal aspects; El sistema de generacion termoelectrico en Panama: Contaminacion atmosferica, aspectos generales y legales. Mexico: N. p., 1996. Web.
Milciades, Concepcion. The Panama fossil power plants generation system: Atmospheric pollution, general and legal aspects; El sistema de generacion termoelectrico en Panama: Contaminacion atmosferica, aspectos generales y legales. Mexico.
Milciades, Concepcion. 1996. "The Panama fossil power plants generation system: Atmospheric pollution, general and legal aspects; El sistema de generacion termoelectrico en Panama: Contaminacion atmosferica, aspectos generales y legales." Mexico.
@misc{etde_335145,
title = {The Panama fossil power plants generation system: Atmospheric pollution, general and legal aspects; El sistema de generacion termoelectrico en Panama: Contaminacion atmosferica, aspectos generales y legales}
author = {Milciades, Concepcion}
abstractNote = {The Thermal electric energy resource of Panama is administered by four Regional Managements and a group of Regional Systems comprising the fossil power plants supplying electric energy to the country`s marginal areas. The characteristics of the different fuels used in these fossil power plants, the results of the assessment of the polluting particles and sulfur and nitrogen oxides are presented. Finally, the alleviation measures and the environmental legislation implanted in these power plants are also presented [Espanol] El parque termico de Panama es administrado por cuatro Gerencias Regionales y un conjunto de Sistemas Regionales que comprenden las plantas termicas de menor capacidad destinadas a suplir de energia a las areas marginadas del pais. Se presentan las caracteristicas de los diferentes combustibles utilizados en estas unidades termicas; los resultados de las mediciones de particulas contaminantes y de oxidos de azufre y oxidos de nitrogeno. Por ultimo se presentan las medidas de mitigacion y legislacion ambiental implantadas en estas centrales termoelectricas}
place = {Mexico}
year = {1996}
month = {Dec}
}