Abstract
The direct measurement of metal temperatures during operation in superheater, reheater, and water wall tubes in zones exposed to high thermal flows is of great interest for the operation and analysis of the correct functioning of a steam generator. The operation temperature measurement of these zones differs very much of the monitored temperature in headers in the dead chamber, since the temperature measured in this zone is the steam temperature that does not reflect the one detected in the gas zone. For this reason, the thermocouples implant in gas zones will detect the real metal temperature and the incidence that some operation variables might have on it (Martinez et al., (1990). [Espanol] La medicion directa de temperaturas de metal durante operacion en tubos de sobrecalentador, recalentador y pared de agua en zonas expuestas a altos flujos termicos es de gran interes para la operacion y analisis del buen funcionamiento de un generador de vapor. La medicion de la temperatura de operacion de estas zonas, difiere mucho de la temperatura monitoreada en cabezales en zona de camara muerta, ya que la temperatura registrada en esta zona es la de vapor que no es un reflejo de la detectada en zona de
More>>
Huerta Espino, Mario;
Martinez Flores, Marco Antonio;
Martinez Villafane, Alberto;
Porcayo Calderon, Jesus;
Gomez Guzman, Roberto;
Reyes Cervantes, Fernando
[1]
- Instituto de Investigaciones Electricas, Cuernavaca (Mexico)
Citation Formats
Huerta Espino, Mario, Martinez Flores, Marco Antonio, Martinez Villafane, Alberto, Porcayo Calderon, Jesus, Gomez Guzman, Roberto, and Reyes Cervantes, Fernando.
Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos.
Mexico: N. p.,
1990.
Web.
Huerta Espino, Mario, Martinez Flores, Marco Antonio, Martinez Villafane, Alberto, Porcayo Calderon, Jesus, Gomez Guzman, Roberto, & Reyes Cervantes, Fernando.
Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos.
Mexico.
Huerta Espino, Mario, Martinez Flores, Marco Antonio, Martinez Villafane, Alberto, Porcayo Calderon, Jesus, Gomez Guzman, Roberto, and Reyes Cervantes, Fernando.
1990.
"Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos."
Mexico.
@misc{etde_334140,
title = {Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos}
author = {Huerta Espino, Mario, Martinez Flores, Marco Antonio, Martinez Villafane, Alberto, Porcayo Calderon, Jesus, Gomez Guzman, Roberto, and Reyes Cervantes, Fernando}
abstractNote = {The direct measurement of metal temperatures during operation in superheater, reheater, and water wall tubes in zones exposed to high thermal flows is of great interest for the operation and analysis of the correct functioning of a steam generator. The operation temperature measurement of these zones differs very much of the monitored temperature in headers in the dead chamber, since the temperature measured in this zone is the steam temperature that does not reflect the one detected in the gas zone. For this reason, the thermocouples implant in gas zones will detect the real metal temperature and the incidence that some operation variables might have on it (Martinez et al., (1990). [Espanol] La medicion directa de temperaturas de metal durante operacion en tubos de sobrecalentador, recalentador y pared de agua en zonas expuestas a altos flujos termicos es de gran interes para la operacion y analisis del buen funcionamiento de un generador de vapor. La medicion de la temperatura de operacion de estas zonas, difiere mucho de la temperatura monitoreada en cabezales en zona de camara muerta, ya que la temperatura registrada en esta zona es la de vapor que no es un reflejo de la detectada en zona de gases. Por esta razon, la implantacion de termopares en zona de gases detectara la temperatura de metal real y la incidencia que algunas variables de operacion tengan sobre esta (Martinez et al., 1990).}
place = {Mexico}
year = {1990}
month = {Dec}
}
title = {Metal temperature monitoring in corrosive gases at high temperature and high thermal flows; Monitoreo de temperaturas de metal en gases corrosivos a alta temperatura y altos flujos termicos}
author = {Huerta Espino, Mario, Martinez Flores, Marco Antonio, Martinez Villafane, Alberto, Porcayo Calderon, Jesus, Gomez Guzman, Roberto, and Reyes Cervantes, Fernando}
abstractNote = {The direct measurement of metal temperatures during operation in superheater, reheater, and water wall tubes in zones exposed to high thermal flows is of great interest for the operation and analysis of the correct functioning of a steam generator. The operation temperature measurement of these zones differs very much of the monitored temperature in headers in the dead chamber, since the temperature measured in this zone is the steam temperature that does not reflect the one detected in the gas zone. For this reason, the thermocouples implant in gas zones will detect the real metal temperature and the incidence that some operation variables might have on it (Martinez et al., (1990). [Espanol] La medicion directa de temperaturas de metal durante operacion en tubos de sobrecalentador, recalentador y pared de agua en zonas expuestas a altos flujos termicos es de gran interes para la operacion y analisis del buen funcionamiento de un generador de vapor. La medicion de la temperatura de operacion de estas zonas, difiere mucho de la temperatura monitoreada en cabezales en zona de camara muerta, ya que la temperatura registrada en esta zona es la de vapor que no es un reflejo de la detectada en zona de gases. Por esta razon, la implantacion de termopares en zona de gases detectara la temperatura de metal real y la incidencia que algunas variables de operacion tengan sobre esta (Martinez et al., 1990).}
place = {Mexico}
year = {1990}
month = {Dec}
}