You need JavaScript to view this

Prefeasibility analysis of a cogeneration project in the Mexican food industry; Analisis de prefactibilidad de un proyecto de cogeneracion en la industria alimenticia mexicana

Abstract

The main technical and economical results of a prefeasibility study of an industry considered of medium size in the food area, which is a subsidiary of an American industrial merger, are shown. The above mentioned facility is located in the highland zone, its installed capacity is 2,350 electrical kw and 8,519 thermal kw needed for the optimum development of the productive process. Five technically feasible cogeneration options are analyzed, comparing the advantages and disadvantages of each option. Guides and conclusions for this type of projects are presented . [Espanol] Se muestran los principales resultados tecnicos y economicos de un estudio de prefactibilidad de una industria considerada como mediana de la rama alimenticia, la cual es filial de un consorcio industrial norteamericano. La planta mencionada se encuentra localizada en la zona del altiplano, cuya capacidad instalada es de 2,350 kW electricos y 8,519 kW termicos necesarios para el desarrollo optimo del proceso productivo. Se analizan cinco alternativas de cogeneracion tecnicamente viables, comparando las ventajas y desventajas de cada alternativa. Se presentan las recomendaciones y conclusiones para este tipo de proyectos.
Authors:
Gongora Gonzalez, Guillermo; Castelazo Hernandez, Arturo [1] 
  1. Ultra Energia, S. A. de C. V. Naucalpan (Mexico)
Publication Date:
Dec 31, 1993
Product Type:
Miscellaneous
Report Number:
CONF-931105-
Reference Number:
SCA: 320304; PA: MX-98:000079; EDB-99:041567; SN: 98002000593
Resource Relation:
Conference: 14. national seminar on the rational use of the energy and exposition of equipment and services, 14. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios, Mexico (Mexico), Nov 1993; Other Information: PBD: 1993; Related Information: Is Part Of 14. national seminar on the rational use of the energy and exposition of equipment and services. Transactions; PB: 426 p.; 14. seminario nacional sobre el uso racional de la energia y exposicion de equipos y servicios. Memoria tecnica
Subject:
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; COGENERATION; FEASIBILITY STUDIES; FOOD INDUSTRY; COST BENEFIT ANALYSIS; NUMERICAL DATA
OSTI ID:
331604
Country of Origin:
Mexico
Language:
Spanish
Other Identifying Numbers:
Other: ON: DE99717747; TRN: MX9800079
Availability:
Available from Asociacion de Tecnicos y Profesionistas en Aplicacion Energetica (ATPAE), Av. Revolucion 728, Oficina 15, Col. Nonoalco Mixcoac, C.P. 03700, Mexico D. F. (Mexico), Tel./Fax: (5) 611 9280; OSTI as DE99717747
Submitting Site:
MX
Size:
pp. 25-34
Announcement Date:
Apr 28, 1999

Citation Formats

Gongora Gonzalez, Guillermo, and Castelazo Hernandez, Arturo. Prefeasibility analysis of a cogeneration project in the Mexican food industry; Analisis de prefactibilidad de un proyecto de cogeneracion en la industria alimenticia mexicana. Mexico: N. p., 1993. Web.
Gongora Gonzalez, Guillermo, & Castelazo Hernandez, Arturo. Prefeasibility analysis of a cogeneration project in the Mexican food industry; Analisis de prefactibilidad de un proyecto de cogeneracion en la industria alimenticia mexicana. Mexico.
Gongora Gonzalez, Guillermo, and Castelazo Hernandez, Arturo. 1993. "Prefeasibility analysis of a cogeneration project in the Mexican food industry; Analisis de prefactibilidad de un proyecto de cogeneracion en la industria alimenticia mexicana." Mexico.
@misc{etde_331604,
title = {Prefeasibility analysis of a cogeneration project in the Mexican food industry; Analisis de prefactibilidad de un proyecto de cogeneracion en la industria alimenticia mexicana}
author = {Gongora Gonzalez, Guillermo, and Castelazo Hernandez, Arturo}
abstractNote = {The main technical and economical results of a prefeasibility study of an industry considered of medium size in the food area, which is a subsidiary of an American industrial merger, are shown. The above mentioned facility is located in the highland zone, its installed capacity is 2,350 electrical kw and 8,519 thermal kw needed for the optimum development of the productive process. Five technically feasible cogeneration options are analyzed, comparing the advantages and disadvantages of each option. Guides and conclusions for this type of projects are presented . [Espanol] Se muestran los principales resultados tecnicos y economicos de un estudio de prefactibilidad de una industria considerada como mediana de la rama alimenticia, la cual es filial de un consorcio industrial norteamericano. La planta mencionada se encuentra localizada en la zona del altiplano, cuya capacidad instalada es de 2,350 kW electricos y 8,519 kW termicos necesarios para el desarrollo optimo del proceso productivo. Se analizan cinco alternativas de cogeneracion tecnicamente viables, comparando las ventajas y desventajas de cada alternativa. Se presentan las recomendaciones y conclusiones para este tipo de proyectos.}
place = {Mexico}
year = {1993}
month = {Dec}
}